c)
Cancel the timer
Touching the heating zone slider control that you want to
cancel the timer
Touching the "-" and "+" together, the timer is
cancelled, and the "00" will show in the minute
display.
Power Management Function
•
it is possible to set a maximum power absorption level for the induction hob, choosing up to different
power ranges.
•
induction hobs are able to limit themselves automatically in order to work at lower power level, to
avoid the risk of overloading.
Turn on the hob, then Press at the same time the
Pause key and Timer "
press +/- of the timer
or
Press at the same time Pause key and Timer "
for confirmation.
To enter Power Management Function
".
To switch to another level
Confirmation and Exit Power Management Function
The timer indicator will show " P5" which means
power level 5。The default mode is on 7.0Kw。
There are 5 power levels, from "P1" to "p5". The
timer indicator will show one of them.
"P1" : the maximum power is 2.5Kw.
"P2" : the maximum power is 3.5Kw.
"P3" : the maximum power is 4.5Kw.
"P4" : the maximum power is 5.5Kw.
"P5" : the maximum power is 7.0Kw.
"
Then the hob will be turned off.
12