eNet
eNet radiografische jaloezieactor 1-voudig mini
Motoren
Aansluiting
massief
soepel met adereindhuls
Afmeting Ø×H
Radiofrequentie
Zendvermogen
Zenderbereik in vrije veld
Ontvangercategorie
6.2 Parameterlijst
De apparaatparameters kunnen met de eNet-server worden veranderd:
Settings window
Device settings
Parameters
Manual commissioning
Repeater mode
Settings, channel
Parameters
Manual commissioning
Operating mode
Local Operation
Behaviour on voltage return
82581433
J0082581433
Setting options, Basic set-
ting
On, Off
Basic setting: On
On, Off
Basic setting: Off
Setting options, Basic set-
ting
On, Off
Basic setting: On
Roller shutter
Venetian blind
Awning
Basic setting: Roller shutter
On, Off
Basic setting: On
No change
Configured value
Basic setting: No change
6/9
0,75 ... 4 mm²
0,75 ... 2,5 mm²
868,0 ... 868,6 MHz
max. 20 mW
Explanations
Disables manual commissio-
ning for all device channels. In
the "Off" setting, the device
cannot be reset to the factory
setting.
In addition to its other functi-
ons, the device can be used
as a repeater. In the "On" set-
ting, the device repeats all the
received telegrams.
Explanations
Blocks manual commissioning
for the device channel. In the
"Off" setting, the device can-
not be reset to the factory set-
ting.
Roller shutter
A rolling shutter or an awning
is controlled for which the
Fabric stretching function is
required.
Venetian blind
A Venetian blind is controlled.
Awning
An awning is controlled for
which the Fabric stretching
function is required.
Blocks the output for operation
using the Prog button.
Defines the behaviour of the
output after voltage return.
RMD design: Bus voltage
return
1000 W
53×28 mm
typ. 100 m
2
04.08.2016