8 Technische gegevens
Vertaling van tekst op bedradingsschema
Engels
(1) Main power connection
For preferential kWh rate power
supply
Indoor unit supplied from outdoor Binnenunit gevoed door buiten
Normal kWh rate power supply
Only for normal power supply
(standard)
Only for preferential kWh rate
power supply (outdoor)
Outdoor unit
Preferential kWh rate power
supply contact: 16 V DC
detection (voltage supplied by
PCB)
SWB
Use normal kWh rate power
supply for indoor unit
(3) User interface
Only for LAN adapter
Only for remote user interface
EKRUDAS
(4) Domestic hot water tank
Anti-legionella heater power
supply
SWB
Ext. thermistor(5)
SWB
Field supplied options(6)
12 V DC pulse detection (voltage
supplied by PCB)
230 V AC supplied by PCB
Continuous
DHW pump output
DHW pump
Electrical meters
For safety thermostat
Inrush
Installatiehandleiding
26
Vertaling
(1) Aansluiting
hoofdstroomtoevoer
Voor elektrische voeding met
kWh-voorkeurtarief
Elektrische voeding met normaal
kWh-tarief
Alleen voor normale voeding
(standaard)
Alleen voor elektrische voeding
met voorkeur kWh-tarief (buiten)
Buitenunit
Contact voor de voeding met
voorkeur kWh-tarief: 16 V DC-
detectie (spanning geleverd door
printplaat)
Schakelkast
Gebruik elektrische voeding met
normaal kWh-tarief voor
binnenunit
(3) Gebruikersinterface
Alleen voor de LAN-adapter
Alleen voor de
gebruikersinterface gebruikt als
kamerthermostaat (EKRUDAS)
(4) Warmtapwatertank
Elektrische voeding voor anti-
legionellaverwarming
Schakelkast
(5) Externe thermistor
Schakelkast
(6) Niet meegeleverde opties
12 V DC pulsdetectie (spanning
geleverd door printplaat)
230 V AC geleverd door
printplaat
Continue stroom
Uitgang pomp voor warm
tapwater
Pomp voor warm tapwater
Elektriciteitsmeters
Voor veiligheidsthermostaat
Inschakelstroomstoot
Engels
Max. load
Normally closed
Normally open
Safety thermostat contact: 16 V
DC detection (voltage supplied
by PCB)
Shut-off valve
SWB
Optional BUH(7)
SWB
Option PCBs(7)
Alarm output
Changeover to ext. heat source
Max. load
Min. load
Only for demand PCB option
Only for digital I/O PCB option
Options: ext. heat source output,
alarm output
Options: On/OFF output
Power limitation digital inputs: 12
V DC / 12 mA detection (voltage
supplied by PCB)
Space C/H On/OFF output
SWB
(8) External On/OFF thermostats
and heat pump convector
Additional LWT zone
Main LWT zone
Only for external sensor (floor/
ambient)
Only for heat pump convector
Only for wired On/OFF
thermostat
Only for wireless On/OFF
thermostat
Vertaling
Maximale belasting
Normaal gesloten
Normaal geopend
Contact voor de
veiligheidsthermostaat: 16 V DC-
detectie (spanning geleverd door
printplaat)
Afsluiter
Schakelkast
(7) Optionele back-upverwarming
Schakelkast
(7) Optionele printplaten
Alarmuitgang
Omschakeling naar externe
warmtebron
Maximale belasting
Minimale belasting
Alleen voor optie vraag-printplaat
Alleen voor optie digitale I/O-
printplaat
Opties: uitgang externe
warmtebron, alarmuitgang
Opties: uitgang AAN/UIT
Digitale inputs
vermogenbeperking: 12 V DC /
12 mA detectie (spanning
geleverd door printplaat)
Uitgang ruimtekoeling/-
verwarming AAN/UIT
Schakelkast
(8) Externe AAN/UIT-
thermostaten en
warmtepompconvector
Aanvoerwatertemperatuur
secundaire zone
Aanvoerwatertemperatuur
primaire zone
Alleen voor ext. sensor (vloer of
omgevings)
Alleen voor
warmtepompconvector
Alleen voor Aan/UIT-thermostaat
met draad
Alleen voor draadloze Aan/UIT-
thermostaat
EHVH04+08S23DAV
Daikin Altherma – Lage-temperatuur-Split
4P499571-1 – 2017.06