Download Inhoudsopgave Inhoud Print deze pagina

FUXTEC FX-GP1600 Handleiding pagina 23

Inhoudsopgave

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 68
Manual_FX_GP_Int24_rev5
Switching on
1. Open all shut-off devices (valve, spray nozzle, water cock) in the pressure line.
2. Insert the plug of the mains cable into the power socket.
3. Switch on the pump at the on / off switch.
Important:
Danger of damage to the pump! A closed pressure line can result in damage to the pump. Do not
allow the pump to run against a closed pressure line.
Switching off
Switch the pump off at the on / off switch after use. Close all the shut-off devices in the pressure
line.
Important:
Danger of injury from hot water. After extended use against the closed pressure side
(> 10 min.), the water in the pump can become very hot and may escape uncontrolled! Disconnect
the pump from the mains supply and allow the pump and water to cool down. Put the pump into
operation again only after all the faults have been remedied!
The risk of injury from hot water can arise in the event of:
- Incorrect installation,
- Closed pressure side,
- Lack of water in the suction line, or
- Defective pressure switch
Procedure in case of overheating
1. Disconnect the pump from the mains supply and allow the pump and water to cool down
2. Check the pump, installation and water level.
3. Put the pump into operation again only after all the faults have been remedied!
23

Advertenties

Inhoudsopgave
loading

Gerelateerde Producten voor FUXTEC FX-GP1600

Deze handleiding is ook geschikt voor:

Fx-gp1800Fx-gp1200n

Inhoudsopgave