ENGLISH
Warning:
This appliance is equipped with a grounded, Type G, 3‐pin power supply cord. This is a safety feature. Do not attempt to
defeat the safety purpose of this plug.
TROUBLESHOOTING
Problem
Not operating
Reduced air flow or poor
filtering.
CLEANING & MAINTENANCE
1. It is recommended to use gloves while discarding the used filter and plastic bag to prevent dust from re‐entering the
air inlet.
2. Release the inlet grill by pressing on the locking switch and pull forward as shown on figure I.
3. Remove the inlet grill from the unit. Figure II
4. Grasp the left and right frame of the HEPA filters through the recess on the side of the filter enclosure, and remove
the filters. Figure III
5. Take the HEPA filter and insert into the unit with the arrow pointing inward. Clean the pre‐filter and inlet grill after
200‐300hours'use, or you can clean it according to the air condition in room. The pre‐filter & inlet grill can be
cleaned with a vacuum, damp cloth or by washing. Figure IV & V
All manuals and user guides at all-guides.com
Reason
1. ON/OFF button has not been pressed.
2. Unit is unplugged
3. The Inlet grill has not been installed and
locked into placed.
1. The Inlet/Outlet grill may be blocked
2. The HEPA filter may be clogged.
1. Press ON/OFF button.
2. Make sure the unit is plugged in.
3. Check the filters are properly installed
and locked into placed.
1. Make sure nothing is in front or top of
the air cleaner.
2. Check the filter indicator of the HEPA
filter if needs replacement.
5