MOTOR
0
1
A
To start and stop the W 70 P and the W
250 P
The motor switch is the button A and the pump switch is
the button B referring to the figure.
•
Push the button (1) to start the product.
•
Push the button (0) to stop the product.
MOTOR
PUMP
0
0
1
1
A
B
Introduction
WARNING:
machines occur during trouble shooting,
service and maintenance as staff have to
locate themselves within the risk area of the
machine. Prevent accidents by being alert
and by planning and preparing the work.
WARNING:
maintenance of the product, make sure that
the motor switch and the pump switch are in
Maintenance
Look for signs of wear,
damage or loose con-
nections of the controls
before the unit is con-
nected.
8
MOTOR
0
1
A
MOTOR
PUMP
0
0
1
1
A
B
Maintenance
Most accidents involving
Before you do
Before each
After every
use
use
X
After use
1. Switch off the suction apparatus with the switch.
2. Disconnect the power cord. Do not remove the pump
cable.
3. Empty and clean the suction apparatus and the
accessories used. Refer to
hose on page 7 and To clean the product on page
9 .
To change the bag
1. Disconnect the power cord and remove the pump
cable.
2. Loosen the 3 toggle fasteners and remove the top.
3. Lift out the float.
4. Remove and dispose the old bag. Refer to local
regulations.
5. Insert the new bag into the stainless steel strainer.
6. Thread the small opening over the internal inlet pipe.
Let the tab rest over the container rim.
7. Do step 1-3 in reversed order.
the Off positions. Disconnect the power cord
and remove the pump cable.
WARNING:
electric components should only be
performed by a licensed electrician.
WARNING:
Risk of dust dispersion.
Maintenance schedule
The maintenance intervals are calculated from daily use
of the product. The intervals change if the product is not
used daily.
Daily
Weekly
X
To attach the suction
All checks that involve
Do not puncture the filter.
6 months or
12 months or
1000h
2000h
1056 - 007 - 09.12.2024