a) Line current measurement
1. Connect the plug to a 230V AC mains socket.
2. Connect the main cable of the load to the socket plug.
3. Put the clamp around the AX1 or AX10 rings and switch the load on
4. Read the value of line current in the AX1 ring or divide by 10 the value of current read in
the AX10 ring.
b) Voltage and power measurement
The ground wire (PE) is used as protection wire.
1. Connect the plug to a 230V AC mains socket.
2. Connect the main cable of the load to the socket plug.
3. Put a power clamp around the AX1 ring and the clamp's test leads in the V inputs of the
instrument then switch the load power on.
4. Read the corresponding values of current, voltage and absorbed power of the connected
load.
Care and cleaning
• Apart from the occasional cleaning the adapter is maintenance free.
• Disconnect the product from the mains before each cleaning.
• Do not use any aggressive cleaning agents, rubbing alcohol or other chemical solutions as
they can cause damage to the housing and malfunctioning.
• Clean the product with a dry, fibre-free cloth.
Disposal
All electrical and electronic equipment placed on the European market must be la-
belled with this symbol. This symbol indicates that this device should be disposed of
separately from unsorted municipal waste at the end of its service life.
Owners of WEEE shall dispose of it separately from unsorted municipal waste.
Spent batteries and accumulators, which are not enclosed by the WEEE, as well
as lamps that can be removed from the WEEE in a non-destructive manner, must
be removed by end users from the WEEE in a non-destructive manner before it is
handed over to a collection point.
Distributors of electrical and electronic equipment are legally obliged to provide free take-back
of waste. Conrad provides the following return options free of charge (more details on our
website):
• at our Conrad stores
• at the collection points established by Conrad
• at the collection points of public waste disposal agencies or at the collection systems set up
by manufacturers and distributors in accordance with the German Electrical and Electronic
Equipment Act.
The end user is responsible for deleting personal data from the WEEE to be disposed of.
It should be noted that different obligations about the return or recycling of WEEE may apply in
countries outside of Germany.
Technical data
Nominal voltage ............................ max. 250 V/AC, 50/60 Hz
Nominal current ............................ max. 16 A
Protection type .............................. IP40
Operating temperature ................. 0 to +40 °C
Operating humidity ....................... max. 80 % up to 31°C
decreasing linearly to 50 % at 40°C
Storage temperature ..................... -20 to +60 °C
Storage humidity ........................... <80 % RH (non condensing)
Altitude .......................................... max. 2100 m
Overvoltage category ................... CAT III 300 V
Dimensions (L x W x H) ................ 225 x 68 x 58 mm
Weight .......................................... approx. 252 g
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights in-
cluding translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication
represent the technical status at the time of printing.
Copyright 2024 by Conrad Electronic SE.
*2435658_v3_1224_02_dm_mh_en