Download Inhoudsopgave Inhoud Print deze pagina

Electric Wiring Diagram; References For Protecting Devices And Cable Specification - AQUARK AllForPools Black Silence BS70 Handleiding

Inhoudsopgave

Advertenties

3. Electric wiring Diagram

a. For power supply: 230V 50Hz
Distribution Box(Customer prepare)
Power Supply
230V 50Hz
Earthing
b. For power supply: 400V 50Hz
Distribution Box(Customer prepare)
Power Supply
400V 50Hz
Earthing
Note: 1)
Must be hard wired, plug is not allowed.
2) The swimming pool heat pump must be earthed well.

4. References for protecting devices and cable specification

MODEL
Rated Current
A
Breaker
Rated Residual
Action Current
mA
Fuse
(A)
2
Power Cord
(mm
)
2
Signal cable
(mm
)
※ Above data is subject to modification without notice.
Note: The above data is adapted to power cord ≤ 10m. If power cord is>10m, wire diameter must be
increased. The signal cable can be extended to 50m maximumly.
Fuse
Breaker
Fuse
Breaker
BS70
BS90
BS110
9
10.5
12
30
30
30
9
10.5
12
3x1.5
3 x 2.5
3 x 2.5
3×0.5
3×0.5
3×0.5
Swimming Pool Heat Pump Wiring Board
Power Cord
Swimming Pool Heat Pump Wiring Board
Power Cord
BS130
BS150
BS170
14.5
16.5
18
30
30
30
14.5
16.5
18
3 x 2.5
3 x 2.5
3 x 4
3×0.5
3×0.5
3×0.5
10
BS210
BS280
BS280S
21
24
9
30
30
30
21
24
9
3 x 4
3 x 6
5 x 2.5
3×0.5
3×0.5
3×0.5
BS350S
12
30
12
5 x 2.5
3 x 0.5

Advertenties

Hoofdstukken

Inhoudsopgave
loading

Inhoudsopgave