General
PCM 40/42 makes it possible to obtain passive cooling
from rock, groundwater or surface soil collectors. When
using a surface soil collector the quality of the ground
may limit the possibility to recover passive cooling.
The ideal climate system is a floor system, which then
becomes a cooling and heating system. Cooling starts
when the external temperature exceeds a preset temper-
ature and is then regulated via a selected cooling curve.
Room temperature sensors can be used for optimum
comfort. The lowest permitted flow temperature should
be chosen to prevent condensation precipitation.
Contents
1 x
Wall bracket
2 x
Screw
1 x
Securing plate
1 x
T-coupling ø22 (only PCM 40)
1 x
T-coupling ø28 (only PCM 42)
All manuals and user guides at all-guides.com
Mounting
Mount the cooling module on the wall.
Use the supplied mounting brackets for wall installation,
which should be screwed into place first, see the follow-
ing illustration. Then mount the cooling module on the
brackets. The cooling module can now be slid sideways
to some extent, which facilitates the fitting of the pipes.
NOTE
Ensure to tighten all connections again, both
inside and outside PCM 40/42, after PCM 40/42
is installed and mounted.
NOTE
Do not use the pipes as a handle.
NOTE
Install the accompanying securing plate any-
where at the bottom rear of the cooling module
for further fastening.