Airfusion QUEST II Installation Instructions
WARNING: FOR YOUR SAFETY ALL ELECTRICAL CONNECTIONS MUST BE UNDERTAKEN BY A
LICENSED ELECTRICIAN.
NOTE: AN ADDITIONAL ALL POLE DISCONNECTION SWITCH MUST BE INCLUDED IN THE FIXED
WIRING.
• Connect "LIVE" supply wire to the "L" of terminal block on the mounting bracket.
• Connect "NEUTRAL" supply wire to the "N" of terminal block on the mounting bracket.
• Connect "EARTH" wire to the "
• Connect the output connector (1) from the receiver to the connector (1) from the fan body.
• Connect the connector (2) from the fan mounting bracket to the input connector (2) from the receiver.
• Connect the connector (3) from from the infrared detecter to the input connector (3) from receiver.
8 | P a g e
ELECTRICAL WIRING DIAGRAM
" of terminal block on the mouthing bracket.
Fig. 8