FAULTS AND DAMAGES
If there is any reason to suspect that the safety of the device has been compromised, it must
be withdrawn from use and removed from any ex-hazardous areas immediately .
Measures must be taken to prevent any accidental restarting of the device .
The safety of the device may be compromised, if for example:
Malfunctions occur .
The housing of the device shows damage .
The device has been subjected to excessive loads .
The device has been stored improperly .
Markings or labels on the device are illegible .
We recommend that a device displaying errors or in which an error is suspected be sent back
to i.safe MOBILE GmbH to be checked .
EX-RELEVANT SAFETY REGULATIONS
Use of this device assumes that the operator observes the conventional safety regulations and
has read and understood manual, safety instructions and certificate .
The following safety regulations must also be complied with:
Inside ex-hazardous areas the covers of all interfaces must be closed .
To ensure the IP-protection, it has to be ensured that the all gaskets are present and functional .
IP protection is not guaranteed anymore if gaps are visible .
The device may only be charged outside ex-hazardous areas using the i.safe PROTECTOR 2.0
or i.safe PROTECTOR 3.0 USB-cable or other equipment approved by i.safe MOBILE GmbH .
Physical connections to other equipment are only allowed outside ex-hazardous areas using
the i.safe PROTECTOR 2.0 or i.safe PROTECTOR 3.0 USB-cable or other equipment approved
by i.safe MOBILE GmbH .
The device may be charged only at ambient temperatures in between +5°C . . . +35°C .
The device must not be exposed to abrasive acids or bases .
The device must not be taken into zones 0 or 20 .
The device shall be protected from impacts with high impact energy and against excessive
UV light emission and high electrostatic charge processes .
Opening the interface covers in explosive atmospheres is not permitted .
EX-RELEVANT SAFETY REGULATIONS FOR NORTH AMERICA
Conditions of Acceptability:
The battery may be charged outside explosion hazardous areas only using approved external
adapter model ICP12-050-2000B with output rated 5Vdc, 2A or other external approved AC/DC
adapter which also complies with the requirements of LPS and has output rated 5Vdc, 2A .
Physical connections to other equipment are only allowed outside ex-hazardous areas .
Opening of any interface or connector covers in explosive atmosphere is not permitted .
The product has been evaluated with rechargeable Li-ion battery pack model MBP93A01 . The
battery is not considered interchangeable .
The device must be protected against excessive UV light emission and high electrostatic
processes .