ELECTRICAL CONNECTION
• The installation of this appliance and the connection to the electrical network should be
entrusted only to an electrician perfectly to the fact of the normative regulations and which
respects them scrupulously.
• Protection against the parts under tension must be ensured after the building-in.
• The data of connection necessary are on the stickers place on the hob casing near the
connection box.
• The connection to the main must be made using a grounded plug or via an omnipolar
circuit breaking device with a contact opening of at least 3 mm.
• The electrical circuit must be separated from the network by adapted devices, for example:
circuit breakers, fuses or contactors.
• If the appliance is not fitted with an accessible plug, disconnecting means must be
incorporated in the fixed installation, in accordance with the installation regulations.
• The inlet hose must be positioned so that it does not touch any of the hot parts of the hob
or even.
Caution!
This appliance has only to be connected to a network 230 V~ 50/60 Hz
Connect always the ground wire.
Respect the connection diagram.
Use the connecting cable that is attached to the device.
The green / yellow wire correspond to the ground wire, the blue wire correspond neutral wire and
the brown wire correspond to the phase.
Mains
Connection
230V~ 50/60Hz
1 Phase + N
400V~ 50/60Hz 2 Phases + N
* calculated with the simultaneous factor following standard EN 60 335-2-6
Connection of the hob
Setting up the configurations:
For the various kinds of connection, use the brass bridges which are in the box next the terminal
Monophase 230V~1P+N
Put a bridge between terminal L1 and L2.
Put a bridge between terminal N1 and N2.
Attach the ground wire to the ground terminal.
Attach the neutral N to one of the terminals N1 or N2.
Attach the Phase L to one of the terminals L1 or L2.
Biphase
400V~2P+N
Put a bridge between terminal N1 and N2.
Attach the ground wire to the ground terminal.
Attach the neutral N to one of the terminals N1 or N2,
Attach the Phase L1 to the terminals L1
Attach the Phase L2 to the terminal L2.
Caution! Ensure that you correctly attach the wires and the bridges and tighten the screws
properly.
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been grounded or has
been equipped with a faulty ground connection.
Cable diameter
H 05 VV - F
2
3 x 2,5 mm
H 05 RR - F
H 05 VV - F
4 x 1.5mm²
H 05 RR - F
44
Cable
Protection calibre
25 A *
16 A *