Removing the insulation

The insulation on PUB2 DS 500 can be removed to facil-
itate work in confined spaces.
Unscrew the lifting eye at the top.
Lift off the plastic top and the top insulation.
Remove the joining plates holding the insulated jacket
halves together. Do not use any tools when dismant-
ling.
Unhook and remove the insulated jacket halves, the
outer diameter of the heater becomes approx. 200
mm less without the insulated jackets.
The figure shows PUB2 DS 500 with
insulation
PUB
Carry out assembly in reverse order.
Install the enclosed insulation plugs around each connec-
tion, and in the hole for the lifting eye. Finally, fit all the
enclosed cover discs on each connection by pressing
them over the connections.
NOTE
Fit the cover discs and the insulation plugs be-
fore installing the pipe.
NOTE
In certain cases, more insulation plugs are en-
closed than are required.
PUB2/PUB2 DS 160-500 | GB
Do not use any tools when dismant-
ling the joining plate.
Insulation removed