- GB -
System message
Functions that are still
available
E
r
3
3
E
r
3
3
20 cleaning cycles in
−
succession
−
60
Possible cause
Manual cleaning
Level detection device stuck or
Time-dependent cleaning
defective
Screen elements heavily soiled
Rinsing pump not operating
Rinsing nozzles clogged
Filter drum not rotating
Gravity fed systems only:
Water level is beneath the level
detection device
Level detection device set too high
Water level in the system too low:
Excessive flow quantity (pump
−
capacity too high)
Water supply too low
−
Water inlet blocked
−
Pump fed system only:
Level detection device set too low
Water level in the system too high:
Outlet pipes soiled
−
Outlet opening too small
−
Excessive flow quantity (pump
−
capacity too high)
Remedy
Clean the level detection device to ensure that the
mechanics operate freely, replace if necessary
Clean and decalcify screen elements (→ Replacing screen
element)
Clean the bottom of the container, clean the rinsing
−
pump(
Cleaning/disassembling the rinsing pump)
Check the pump connection
−
Clean the rinsing nozzles
Check the motor connection
−
Check the rotating movement of the filter drum. To do so,
−
check the markings (1 - 8) on the filter drum to detect a
rotating movement.
Increase the water level of the pond
−
Use the OASE ProfiClear Guard refill system
−
Adjust the level detection device (→ Adjusting the level
detection device)
Reduce flow quantity (adjust pump capacity)
−
Select a larger pipe diameter for the water supply if
−
necessary
Clean water inlet
−
Adjust the level detection device (→ Adjusting the level
detection device)
Clean outlet pipes
−
Enlarge outlet opening
−
Reduce flow quantity (adjust pump capacity)
−
Resetting the system
message
On|Off
Press key
for 5 sec