EN – Installer information
Electrical
connection
100–240V AC
8
ELECTRICAL CONNECTION 100–240VAC
NB! Wiring of 100–240 V AC must be performed
by a qualified electrician.
Norte auto:
100–240 V AC 50 / 60Hz
Factory-set for continuous basic ventilation, auto-
matic forcing at elevated humidity levels and under
the influence of changes in light.
Possibility to start / stop via manual switch T.
Norte switch-operated, with run-on time:
(Can be combined with backdraught shutter)
100–240 V AC 50/60 Hz
Must be selected via Pax App.
Start/stop via manual switch T.
Norte humidity-controlled:
(Can be combined with backdraught shutter)
100–240 V AC 50/60 Hz
Must be selected via Pax App.
Basic setting, automatic start/stop at changes in
humidity level.
Possibility to start / stop via manual switch T.
Norte heat distributor:
100–240 V AC 50/60Hz
Must be selected via Pax App.
Basic settings, starts at 25 ° C, stops at 22 ° C.
Norte switch-operated on / off
(Can be combined with backdraft shutter)
100–240 V AC 50 / 60Hz
Must be selected via Pax App.
Start / stop via manual switch L.
NB! The integrated all-pole switch S only
functions at 100–240 V AC wiring.
Bluetooth LE: -12dBm EIRP (63µW), nominal 2450MHz.
Radio Equipment Directive (RED)
Pax hereby assure that this type of Bluetooth radio equip-
ment complies with RED Directive 2014/53 / EU.
The full text of the EU Declaration of Conformity can be
found at the following http://pax.se/produkter/
ventilation/badrumsflaktar/calima/1550-1
"LADDA NER" CE_Declaration_Calima_pdf.
T
T
L
100-240VAC
N
S
+
_
12VDC
User and installation instructions
M