9
Troubleshooting
If a problem occurs, always observe the charge-status and fault indicator of the battery. See the section
headed Status indicators of the Liion battery.
If the trouble you are experiencing is not listed in this table or you are unable to rectify the problem by
yourself, please contact Hilti Service.
Trouble or fault
Battery does not engage with
an audible click.
Overload LED flashes for 10
seconds.
Blind rivet is not set.
No rivet mandrel disposal.
10
Disposal
WARNING
Risk of injury due to incorrect disposal! Health hazards due to escaping gases or liquids.
▶ DO NOT send batteries through the mail!
▶ Cover the terminals with a non-conductive material (such as electrical tape) to prevent short circuiting.
▶ Dispose of your battery out of the reach of children.
▶ Dispose of the battery at your Hilti Store, or consult your local governmental garbage disposal or public
health and safety resources for disposal instructions.
Most of the materials from which Hilti products are manufactured can be recycled. The materials must be
correctly separated before they can be recycled. In many countries, your old tools, machines or appliances
can be returned to Hilti for recycling. Ask Hilti Service or your Hilti sales representative for further information.
▶ Do not dispose of power tools, electronic equipment or batteries as household waste!
11
Manufacturer's warranty
▶ Please contact your local Hilti representative if you have questions about the warranty conditions.
12
Further information
For more information on operation,
qr.hilti.com/manual/?id=2293235&id=2293236
This link is also to be found at the end of the documentation, in the form of a QR code.
*2293235*
Possible cause
The retaining lugs on the battery
are dirty.
Overload protection.
Battery is discharged.
Jaws are dirty or worn.
Jaw housing not correctly screwed
on.
Spring weak or defective.
Use of the wrong nosepiece.
Nosepiece is worn.
Rivet mandrel wedged in jaws.
Steel sleeve is dirty.
Mandrel container is full.
technology,
2293235
Action to be taken
▶ Clean the retaining lug and
re-insert the battery.
▶ Remove metallic residues. 23
▶ Change the battery and charge
the empty battery.
▶ Clean the jaws or, if applicable,
replace them. 23
▶ Screw the jaw housing on
correctly . 24
▶ Replace the spring . 23
▶ Change the nosepiece. 22
▶ Change the nosepiece. 22
▶ Remove the rivet-mandrel
residues from the jaw housing .
24
▶ Clean the steel sleeve . 23
▶ Empty the mandrel container .
22
environment and recycling,
follow this link:
English
25