Maintenance
Clean the controller only with soapy water.
Storage
In the event of prolonged non-use, remove the battery from the controller. The controller must be
stored in a frost-free place.
Diagnostics and repairs
The pump does not operate
Diagnostics:
The battery is defective or improperly installed.
The pump operates but does not pressurise
Diagnostics:
Sealing fault in the couplings
The hose is damaged
The checker is damaged (in a fall for example)
Guarantee
The controller is guaranteed for 2 years except for the battery and the hose.
Damage caused by leakage of a non-compliant battery is excluded from the guarantee.
Spare parts
Designation
Hose
1/2 GAZ coupling
7/8 GAZ coupling
M20-150 coupling
Bag
Hose ends (2)
12
Problem-solving:
Install a new 1.5 Volt alkaline battery type AA –
LR6 as indicated in the photograph, with the
correct polarities. If the problem persists, return
the cotroller to VIRAX After-Sales Service.
Problem-solving:
Check the tightening of the couplings. (the
knurled parts must be tightened by hand)
Fold the free end of the hose and check the
pressurisation; repeat the operation by
reversing the end connected to the controller.
Check the operation of the controller by
screwing a vehicle valve stopper in place of the
hose. If the controller does not pressurise
return it to VIRAX After-Sales Service.
Code
752964
752965
752966
752967
752968
752969