Download Inhoudsopgave Inhoud Print deze pagina

Flotec AUTOJET 1000 Handleiding Voor Gebruik En Onderhoud pagina 9

Inhoudsopgave

Advertenties

WARNING
WARNING
Technical Data
Mains voltage / frequency
Absorbed power
Type of protection / Insulation class
Suction fitting
Delivery fitting
Maximum flow rate
Maximum head
Maximum suction height
Power cable
Weight
Maximum admitted working pressure
Minimum ambient temperature
Maximum ambient temperature
Maximum temperature of the pumped fluid
Maximum number of starts per hour
Sound power level (Lwa)**
Sound pressure level (Lpa)
Sound emission values obtained in conformity with the EN 12639 standard
**Measurement method according to EN ISO 3744
(*) The specifications above are referred to a configuration with a free and unreduced delivery mouth.
Ch. 3 Installation (see Fig. 1)
DANGER
Electric shock
risk
WARNING
DANGER
DANGER
Use a suction pump (2) with a diameter equivalent to that of the suction mouth of the electropump (1).
If the height (HA) is over 4 meters use a tube with a larger diameter. The suction line should be perfectly airtight.
No elbows and/or slopes should be present to prevent the formation of air locks that could affect the electropump
efficiency. A foot valve (3) with filter (4) should be fitted at about half a metre below the fluid that has to be pumped (HI)
on one end of the line. Load losses can be reduced using delivery piping with a diameter equivalent or greater than the
electropump mouth (5). It is advisable to install a check valve (6) directly on the delivery line to prevent the electropump
being damaged by "water hammer".
The pump cannot be used for sea water and inflammable, corrosive, explosive or
dangerous liquids.
Verify that the electropump never runs without liquids.
When installing, please ensure electropump is disconnected from electrical
supply. Pumps in this series are not suitable for use in a swimming pool and
the relevant cleaning and servicing operations.
Protect the electropump and all pipes from bad weather or freezing conditions.
To prevent possible injuries to people, avoid inserting hands into the mouth of the pump if
this is connected to the mains.
This appliance can be used by children aged 8 years or over and by persons with limited
physical, sensory or intellectual capabilities, or with limited experience and knowledge,
provided that they are supervised or have been instructed in the safe use of the appliance
and are aware of the dangers involved. Children must not be allowed to play with the
appliance. Cleaning and user maintenance must not be carried out by children unless
they are supervised
AUTOJET 1000
230 V ~ 50 Hz
800 Watt
IPX4 / F
33,25 mm (1"M)
33,25 mm (1"M)
3.300 l/h
46 m
7 m including load losses
1,5 m H07 RNF
9,8 Kg
6 bar
5° C
40° C
50° C
40, uniformly distributed
89 dB
76,5
2
GB
AUTOJET 1500
230 V ~ 50 Hz
1100 Watt
IPX4 / F
33,25 mm (1"F)
33,25 mm (1"F)
4.200 l/h
45 m
7 m including load losses
1,5 m H07 RNF
10,5 Kg
6 bar
5° C
40° C
50° C
40, uniformly distributed
82 dB
70,1
GB
7

Advertenties

Hoofdstukken

Inhoudsopgave
loading

Deze handleiding is ook geschikt voor:

Autojet 1500

Inhoudsopgave