Use only System Milwaukee 18 V chargers for charging
System Milwaukee 18 V battery packs. Do not use battery
packs from other systems.
Never break open battery packs and chargers and store
only in dry rooms. Keep dry at all times.
Battery acid may leak from damaged batteries under
extreme load or extreme temperatures. In case of contact
with battery acid wash it off immediately with soap and
water. In case of eye contact rinse thoroughly for at least
10 minutes and immediately seek medical attention.
Warning! To reduce the risk of fi re, personal injury, and
product damage due to a short circuit, never immerse your
tool, battery pack or charger in fl uid or allow a fl uid to fl ow
inside them. Corrosive or conductive fl uids, such as
seawater, certain industrial chemicals, and bleach or
bleach containing products, etc., can cause a short circuit.
SPECIFIED CONDITIONS OF USE
The Band Saw cuts lengthways and mitre accurately in
diff erent type of metals such as metal profi les (UniStrut),
pipes, metal studs, channels, aluminium profi les, metal
sheets.
Do not use this product in any other way as stated for
normal use.

EC-DECLARATION OF CONFORMITY

We declare under our sole responsibility that the product
described under "Technical Data" fulfi lls all the relevant
regulations and the directives 2011/65/EU (RoHS),
2014/30/EU, 2006/42/EC, and the following harmonized
standards have been used:
EN 60745-1:2009 + A11:2010
EN 60745-2-20:2009
EN 55014-1:2017+A11:2020
EN 55014-2:2015
EN IEC 63000:2018
Winnenden, 2020-11-04
Alexander Krug
Managing Director
Authorized to compile the technical fi le.
Techtronic Industries GmbH
Max-Eyth-Straße 10
71364 Winnenden
Germany
GB-DECLARATION OF CONFORMITY
We declare as the manufacturer under our sole responsibility
that the product described under "Technical Data" fulfi lls all
the relevant provisions of the following Regulations S.I.
2008/1597 (as amended), S.I. 2016/1091 (as amended), S.I.
2012/3032 (as amended) and that the following designated
standards have been used:
BS EN 60745-1:2009 + A11:2010
BS EN 60745-2-20:2009
BS EN 55014-1:2017+A11:2020
BS EN 55014-2:2015
BS EN IEC 63000:2018
Winnenden, 2020-11-04
Alexander Krug
Managing Director
Authorized to compile the technical fi le.
470 650 - M18FBS85.indd 25
470 650 - M18FBS85.indd 25
Techtronic Industries GmbH
Max-Eyth-Straße 10
71364 Winnenden
Germany

BATTERIES

Battery packs which have not been used for some time
should be recharged before use.
Temperatures in excess of 50°C (122°F) reduce the
performance of the battery pack. Avoid extended exposure
to heat or sunshine (risk of overheating).
The contacts of chargers and battery packs must be kept
clean.
To obtain the longest possible battery life remove the
battery pack from the charger once it is fully charged.
For battery pack storage longer than 30 days:
Store the battery pack where the temperature is below
27°C and away from moisture
Store the battery packs in a 30% - 50% charged condition
Every six months of storage, charge the pack as normal.
BATTERY PACK PROTECTION
In extremely high torque, binding, stalling and short circuit
situations that cause high current draw, the tool will stop for
about 2 seconds and then the tool will turn OFF.
To reset, release the trigger.
Under extreme circumstances, the internal temperatur of
the battery could become to high. If this happens, the
battery will shut down.

TRANSPORTING LITHIUM BATTERIES

Lithium-ion batteries are subject to the Dangerous Goods
Legislation requirements.
Transportation of those batteries has to be done in
accordance with local, national and international provisions
and regulations.
• The user can transport the batteries by road without
further requirements.
• Commercial transport of Lithium-Ion batteries by third
parties is subject to Dangerous Goods regulations.
Transport preparation and transport are exclusively to be
carried out by appropriately trained persons and the
process has to be accompanied by corresponding
experts.
When transporting batteries:
• Ensure that battery contact terminals are protected and
insulated to prevent short circuit.
• Ensure that battery pack is secured against movement
within packaging.
• Do not transport batteries that are cracked or leak.
Check with forwarding company for further advice
MAINTENANCE
The ventilation slots of the machine must be kept clear at
all times.
Use only Milwaukee accessories and Milwaukee spare
parts. Should components need to be replaced which have
not been described, please contact one of our Milwaukee
service agents (see our list of guarantee/service
addresses).
If needed, an exploded view of the tool can be ordered.
Please state the machine type printed as well as the
six-digit No. on the label and order the drawing at your
local service agents or directly at: Techtronic Industries
GmbH, Max-Eyth-Straße 10, 71364 Winnenden, Germany.