Technical Data
Voltage ...................................................... 230 V .............................. 230 V
Frequency ................................................. 50 Hz .............................. 50 Hz
Maximum power consumption ................... 750 W ............................. 370 W
Maximum fluid temperature ........................ 60°C ............................... 90°C
Approved pumping media ..........................
Maximum operating pressure ..................... 5,9 bar ............................ 5 bar
Maximum flow rate with
water / heat transfer medium ..................... 35 / 31 l/min .................... 30 / 27 l/min
Diameter return hose / pressure hose ........ ½ / ½ inch ....................... ½ / ½ inch
Tank content .............................................. 30 l ................................. 30 l
Dimensions (height/width/depth) ................ 760 / 490 / 510 mm ........ 760 / 490 / 510 mm
Weight (empty tank) ................................... 23,3 kg ........................... 21,8 kg
Protection class ......................................... I ...................................... I
Protection type Motor ................................. IP 44 ............................... IP 55
Noise pressure level (L
Sound power level (L
The noise level during operation can exceed 85 dB (A). Wear hearing protection!
Measured values determined in accordance with EN 61029-1:2010.
3
Function of the Unit
3.1
Overview
1
Filling hose
2
Return hose
3
Tank
4
Pump outlet
3.2
Transportation and unpacking
After unpacking, immediately check the filling unit for completeness and damage.
Immediately report any transit damage to the supplying company.
Dispose of packaging material according to the respective local regulations.
¦ K
) .................. 72 dB (A) ¦ 3 dB (A) ...... 75 dB (A) ¦ 3 dB (A)
pA
pA
¦ K
) .................... 83 dB (A) ¦ 3 dB (A) ...... 86 dB (A) ¦ 3 dB (A)
WA
WA
ENGLISH
ROSOLAR PUMP
water, heat transfer medium
5
Switch
6
Ball valve
7
Tank lid
8
Filter casing
ROSOLAR PUMP PLUS
(A)
13