2. ELECTRIC SUPPLY
Connect the correct electric supply to the oven as indicated on the nameplate.
The electric supply should be connected to the oven by a professional elec-
trician. The connection of the wires should be tied firmly. The oven should be
in grounding protection. (L1: red or brown, L2: green, L3: White, N: blue, E:
yellow and green)
After the oven has been connected to the electric supply, first of all check the
direction of rotation of the fan. It should rotate clockwise when looking from the
front of the oven. If the rotating direction is adverse, please exchange any two
of the electric cables to reverse the direction.
3. WATER SUPPLY
Please choose a ø 12 X 1mm hose to connect the water inlet and the water
supply. Incoming water pressure should be 1 - 7 kg/cm
3.1. Extraction Hood Connection
Flexible.
NOT INCLUDED
Flexible.
NOT INCLUDED
4
Ø75 mm
Ø12 x 1mm
SINMAG EUROPE BVBA
2.
Ø150 mm
Steam outlet.
On the back or on top.
Water drainage