Technical data 2
Power source
Mains voltage ±10% (50-60Hz), V
Phases
Minimum generator size, kVA
Minimum short-circuit power, MVA
1)
Fuse, A
Mains current effective, A
Mains current max., A
Power 100%, kVA
Power max., kVA
Power open circuit, W
Efficiency, %
Power factor
Current range, A
Duty cycle 100% 40°C, A/V
Duty cycle 60% 40°C, A/V
Duty cycle max. 40°C, A/%/V
Open circuit voltage, V
2)
Sphere of application
Protection class
3)
Standards
Dimensions (HxWxL), mm
Weight, kg
Wire feed speed, m/min
Torch connection
Wire dimension, mm
Wire spool diameter, mm
Wire spool, kg
Gas pressure, max., MPA (bar)
* Power sources with a maximum power consumption of 10 A and 2.5 mm² supply cable can be used at more than one fuse size
FUNCTION
Selection of trigger mode, 2-times / 4-times
Gas pre-flow, sec.
Soft-start, m/min
Hot-start, %
Hot-start-time, sec.
Slope down time, sec.
Final current, %
Final current time, sec.
Gas post-flow, sec
Spot welding time, sec.
Step welding time, sec.
DUO Plus™ value
Electronic choke
1) This equipment complies with EN / IEC61000-3-12:2014 (/ 2011) provided that the short-circuit power Ssc of the grid at the interface point is greater than or equal to the stated
data in the abovementioned table. It is the responsibility of the installer or user of the equipment to ensure, by consultation with the distribution network operator if necessary,
that the equipment is connected only to a supply with a short-circuit power Ssc greater than or equal to the stated data in the abovementioned table.
2) S This machine meets the demand made for machines which are to operate in areas with increased hazard of electric chocks.
3) The machine is designed for indoor and outdoor use according to protection class IP23S. The machine may be stored but is not intended to be used outside during precipitation
unless sheltered.
CMI 300 Pulse Boost
380-440
208-380
380-440
208-380
3
3
1
1
16
16
10
9
3.75
10/16/20* 20
10/16/20* 20
9.6
17.3
10.5
19.8
16.6
32.2
15.2
29.2
7.0
7.1
3.9
4.0
10.6
11.0
6.0
6.1
16
45
45
45
87
82
82
80
0.95
0.95
0.98
0.98
15-230
15-200
200/24.0
150/21.5
210/24.5
160/22.0
300/20/29.0
200/40/24.0
50-60
S/CE
IP23S
IEC60974-1. IEC60974-5. IEC60974-10 Cl. A
838x443x1003
52
0.5-30.0
EURO
0.6-1.6
300
5-18
0.6(6.0)
PROCESS
VALUE RANGE
MIG/MAG
2/4
MIG/MAG
0-10
MIG/MAG
0.5-24.0
Synergic
-99-(+)99
Synergic
0-20
Synergic
0-10
Synergic
0-100
Synergic
0-10
MIG
0-20
MIG
0.1-5.0
MIG
0.1-5.0
MIG
1-50
MIG
-5-(+)5
CMI 300 Pulse Twin Boost
380-440
208-380
380-440
208-380
3
3
1
1
16
16
10
9
3.75
10/16/20* 20
10/16/20* 20
9.6
17.3
10.5
19.8
16.6
32.2
15.2
29.2
7.0
7.1
3.9
4.0
10.6
11.0
6.0
6.1
16
50
50
45
87
82
82
80
0.95
0.95
0.98
0.98
15-300
15-200
200/24.0
150/21.5
210/24.5
160/22.0
300/20/29.0
200/40/24.0
50-60
S/CE
IP23S
IEC60974-1. IEC60974-5. IEC60974-10 Cl. A
1104x597x1003
66
0.5-30.0
EURO
0.6-1.6
2x300
2x5-18
0.6 (6.0)
hereby declare that our machine as stated below
Type: CMI Pulse
conforms to directives: 2014/35/EU
European standards:
Regulation:
21
CMI 300 Pulse Trio Boost
380-440
208-380
380-440
208-380
3
3
1
1
16
16
10
9
3.75
10/16/20* 20
10/16/20* 20
9.6
17.3
10.5
19.8
16.6
32.2
15.2
29.2
7.0
7.1
3.9
4.0
10.6
11.0
6.0
6.1
16
55
55
45
87
82
81
80
0.95
0.95
0.98
0.98
15-300
15-200
200/24.0
150/21.5
210/24.5
160/22.0
300/20/29.0
200/40/24.0
50-60
S/CE
IP23S
IEC60974-1. IEC60974-5. IEC60974-10 Cl. A
1104x597x1003
70
0.5-30
EURO
0.6-1.6
3x200
3x5
0.6 (6.0)
EC DECLARATION OF CONFORMITY
CAR-O-LINER GROUP AB
Sweden
2014/30/EU
2011/65/EU
EN IEC60974-1:2018/A1:2019
EN IEC60974-5:2019
EN IEC60974-10:2014/A1:2015
2019/1784/EU