The system functions
(supply control unit
7
with accumulator)
USE
7
7.1 User safety instructions
Do not hit the glass screen with hard objects!
If the front glass screen cracks, DO NOT touch the product!
7.2 Use of the audio terminals
1 STAND-BY
At the first touch, the keyboard is backlit and the terminal may receive the
following commands:
AUDIO MONITORING
Monitoring duration: 10 sec.
By touching this key, you may listen to what goes on at the entrance, in front of the
outdoor panel. Monitoring is not possible if another terminal of the system is
being called or is during communication.
VOLUME ADJUSTMENT OR
Stand-by
"TERMINAL TURNED OFF"
By successive touches of this key, the 3 volume levels are passed through:
maximum (white LED), medium (red-white LED) and turned off (red LED). The
red LED will remain permanently turned on until the key is pressed again.
2 CALL AND COMMUNICATION
Call duration: maximum 1 min.
The LED of the key blinks.
By touching the key, communication is initiated. The LED does not blink
Call
anymore.
Do not touch the
END COMMUNICATION
WITHOUT ACCESS!
The second touch of the key ends communication without granting access and
the terminal returns to stand-by mode.
All manuals and user guides at all-guides.com
Control unit:
S1: red
S2:
PROG:
ANSWER THE CALL
Communication duration: maximum 2 min.
key during communication.
Lack of tension from the
230Va.c. network
The system functions
powered by the
accumulator.
Check the 10A fuses from
the electrical panel and
the 1,6A Fuse 1 from the
supply control unit input.
Check the continuity of
the supply cables.
28/92