5.1 Installation of the electromagnetic lock (optional)
Drive current (D C)
2 x 0.75 mm²
BUT
LC
LA/C
LA
supply control unit
The supply control unit can supply a current of
max. 1A for the supply of the lock.
The tension of +14 V d.c. is present on the LC
hub of the supply control unit.
The connection of a lock actuating button
from the interior of the building will be made
at the BUT and LC hubs of the supply
control unit.
5.2 Auxiliary command connection (optional)
6
COMMISIONING OF THE SYSTEM
6.1 Description of the supply control unit
The supply control unit includes:
*PROG. : programming button
LED signaling of programming /
Front lid defect within the system
TIME:
Lock timing adjustment
* The KIT does not require programming. This button is used only if you add additional
terminals or panels to the system.
All manuals and user guides at all-guides.com
cable
LC1
LC2
Drive current
electromagnetic lock (DC)
Relay contact
Maximum switched current: 1.5 A
S2
PROG
Video
STROMVERSORGUNGSEINHEIT (SCU.VDN.BLW)
SCHLOSSÖFFNUNGSZEIT
EINGANG: 230V Wechselspannung 50Hz, 0.4A
(sekunden)
1
10
2
AUSGANG 1: 14V, 2A Gleichspannung (S1)
9
3
AUSGANG 2: 14V, 0.5A Gleichspannung (S2)
4
8
7
5
6
Alternative current (AC)
Transformer
230 Va.c.
BUT
LC
LA/C
LA
supply control unit
AUX Command
(automation)
S1: presence of tension at the +14V - GND hubs
S2: existence of tension at the +Uv - GNV hubs
Protection lid for connections
S1
Audio
Front lid
ACHTUNG!
Lebensgefahr,
gerät nicht öffnen!
GEFAHR EINES
STROMSCHL AGS!
Protection lid for connections
12 Va.c.
2 x 0.75 mm²
cable
Alternative current
electromagnetic lock (AC)
25/92