Main menu: Fitter
Sensor
selec-
tion
Sen-
sors
Sensor
type
Calibra-
tion
Important!
In rooms exposed to solar radiation (large
windows), we recommend the function
"room and floor thermostat".
In rooms with wooden floors the function
"room and floor thermostat" must always
be used.
30
Floor sensor
Room sensor
Room sensor + limited
floor
Max. (overheating)
Preset to 30 °C
Adjustable 27–35 °C
Min. (comfort)
Preset to 5 °C
Adjustable (Off)
5–25 °C
Floor sensor + limit.
room
Max (room restriction)
Preset to 25 °C
Adjustable 20–27 °C
NTC 2 kΩ
NTC 10 kΩ
NTC 12 kΩ
NTC 15 kΩ
NTC 22 kΩ
NTC 33 kΩ
NTC 47 kΩ
NTC 100 kΩ
Floor sensor
Room sensor
Tile/stone
Tile/stone
Wood/laminate/
vinyl
Vinyl: max.
28 °C.
Tile/stone
wood/laminate/
vinyl
As a guide, the
current temper-
ature for each
sensor type is
displayed.
If required
the respective
sensors can be
calibrated.