Fitting the eTOUCH-eco
eTOUCH-eco should not be placed so it is
exposed to direct sunlight and draughts
because these can affect the thermostat
functions. Take into account the thermo-
stat IP class when fitting.
The floor sensor is fitted in a spiral tube
placed at the height of the floor surface.
The end of the hose must be sealed in
order to simplify replacement of the floor
sensor.
Fit the thermostat in a 65 mm junction box.
Ensure the box is flush with the wall or
alternatively the tiles.
1. Lift the front panel and frame by push-
ing a screwdriver into the groove on the
underside, see picture. Lift the front panel
upwards until you hear a "click".
2. Connect according to the instructions on
the back of the thermostat. The protective
conductor for incoming supply and heat-
ing cable is connected using a connection
clamp in the box.
22