Installation
PCB from the housing. Loosen the
screw and lift out the PCB.
 Cable opening "5" for external detectors with a connection ca-
ble of max. 10 metres
Approximation and separation distances on ferromagnetic and
non-ferromagnetic mounting sur-faces due to EN 50131-2-6,
chapter 5.2 c
14 |
E N
Open the housing by loosening the
screw and then removing the cover.
Remove the
 Fasten the detector and mag-
net holder centrally to the "3"
marking with a maximum
spacing of 10 mm.
 Use the base plate of the de-
tector and the magnet holder
to mark the fastening holes 1,
4, 6 and 7.
 Use the rounded head screw
for the detector and the coun-
tersunk screw for the magnet
holder.
 Ensure that the anti-removal
wall contact "2" can be moved
inwards..