7.2 Assembly instructions
7.2.1 As a mixing valve:
The flow direction arrows must be observed when con-
necting the hot and cold water inlets.
7.2.2 As a diverter valve:
For this application flow is in the reverse direc-
tion and therefore is in the opposite direction to
the arrows on the housing.
7.2.3 Changing the setting
The mixing valve can be set within the range 30°C to
60°C as follows:
• Remove the protective cap.
• Turn the adjuster knob until the required setting
number aligns with the index mark 8 on the valve
body.
9. Spare Parts
Thermostatic mixing TM200, from 1996 onwards
1
Regulation valve
complete
Honeywell GmbH
GB
8. Disposal
• Dezincification resistant brass housing
• Brass threaded connections
• Moving parts of high-quality, scale-resistant synthe-
• Transparent plastics protective cap
• Plastics adjuster knob
• NBR seals
• Stainless steel spring
10. Accessories
1
KB191-3/4 Return flow-retarder unit
TM200A-30/60
5
tic
material
Observe the local requirements regarding cor-
rect waste recycling/disposal!
KB191
for fitting to systems which include a hot
water circulation circuit - to prevent cold
water backfeeding and cooling the mixed
water at the outlets.
Operating pressure:
Operating temperature: max. 90 °C
Installation orientation: