Download Inhoudsopgave Inhoud Print deze pagina

Setting The Sensitivity - Waeco AirCon Service Multi Gas Gebruiksaanwijzing

Inhoudsopgave

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 46
Multi Gas
7.3

Setting the sensitivity

I
NOTE
 The leak detector responds to all standard refrigerants. If you
use a different refrigerant to R-134a or R-1234yf, select the
R-134a mode.
 Sensitivity level L and R-134a mode are preset.
 If you use the leak detector in a heavily soiled area, press the
start button again after switching on. The device then switches
to a mode for heavily soiled areas. This is indicated by a low-
pitched beep which gets louder as soon as a leak is detected.
The device has four sensitivity levels with increasing sensitivity per
refrigerant (R-1234yf or R-134a):
Refrigerant
Setting
R-134a
L
M
S
R-1234yf
L
M
S
➤ Press the start button (fig. 2 4, page 2) to select the sensitivity level or
to switch between the R-1234yf and R-134a modes.
EN
Operating the leak detector
Refrigerant quantity/leak size
14 g / a (0.5 oz / yr.) or above
7 g / a (0.25 oz / yr.) or above
4 g / a (0.15 oz / yr.) or above
14 g / a (0.5 oz / yr.) or above
7 g / a (0.25 oz / yr.) or above
4 g / a (0.15 oz / yr.) or above
19

Advertenties

Inhoudsopgave
loading

Inhoudsopgave