Download Inhoudsopgave Inhoud Print deze pagina

Operating Conditions - Toya VOREL 81108 Oorspronkelijke Gebruiksaanwijzing

Pneumatische slijpmachine
Inhoudsopgave

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 85
EN
Hazards arising from vapors and dust
Dust and fumes caused by using a pneumatic tool can cause bad health condition (such as cancer, birth defects, asthma and/or infl ammation of the
skin). There are necessary: a risk assessment and implementation of appropriate control measures in relation to those risks. The risk assessment
should include the eff ect of dust created by using tools and the possibility of excitation of the existing dust. The air outlet must be aimed to minimize
generating dust in a dusty environment. Where dust or fumes are created, priority should be to control them at the source of their emission. All
integrated functions and equipment for collection, extraction or reduction of dust or fume should be properly operated and maintained in accordance
with manufacturer's recommendations. Wear suitable respiratory protective equipment, in accordance with the instructions of an employer and in
accordance with the requirements of hygiene and safety. Service and maintenance of the pneumatic tool should be carried out according to the
recommendations of the manual, this will minimize the emission of fumes and dust. You should select, maintain and exchange inserted tools according
to the manual, to prevent increase of and dust. Treatment of certain materials can cause fumes and dust, that produce a risk of explosion.
Noise hazard
Exposure, without any protection, for high noise levels can cause permanent and irreversible hearing loss and other problems, such as tinnitus
(ringing, buzz, whistling or humming in the ears). It is necessary to perform the risk assessment and implement appropriate control measures
in relation to those risks. The appropriate checks, performed in order to reduce the risk, may include activities such as: application of insulation
materials to prevent the "ringing" of the workpiece. Use hearing protection in accordance with the instructions of employer and in accordance with
the requirements of hygiene and safety. Service and maintenance of the pneumatic tool should be carried out according to the recommendations
of the manual, to avoid the unnecessary increase of noise level. If the pneumatic tool has a muffl er, you should always make sure that it is correctly
mounted when you use the tool. Select, maintain and replace worn inserted tools according to the recommendations of the manual. This will allow
to avoid the unnecessary increase in noise.
Risks of vibrations
Exposure to vibration may cause permanent damage to the nerves and blood supply to the hands and arms. You should stay away from the
screw driver sockets. You should wear warm clothing when working at low temperatures and you should keep your hands warm and dry. If you
experience numbness, tingling, pain or skin whitening in the fi ngers and hands, you should discontinue the use of pneumatic tool, and then inform
your employer and seek medical advice. Operation and maintenance pneumatic tool according to the recommendations of the manual, will allow to
avoid the unnecessary increase of vibration. Do not use worn or ill-fi tting caps, because it can cause a signifi cant increase in the level of vibration.
Select, maintain and replace worn inserted tools according to the recommendations of the manual. It will allow to avoid the unnecessary increase of
vibration. Where it is possible the covering assembly should be used. If it is possible, you should subpart the weight of the tool in a rack, tensioner
or equivalent. Hold the tool, with light but a fi rm grip, taking into account the required reaction forces, because the risk from vibration is ususally
much larger, when the grip force is higher. An improperly mounted or damaged inserted tool can cause an increase in vibration.
Additional safety instructions for pneumatic tools
Air under pressure can cause serious injury:
- always shut off the air supply, drain hose of air pressure and detach tool from air supply, when it is not in use, before changing accessories or
performing repairs;
- never direct the air stream at yourself or anyone else.
Hose hitting can cause serious injury. You should always check for damaged or loose hoses and fi ttings. Cold air should be directed away from
the hands
Every time when there are used universal screwed connection (claw couplings), you should apply the protecting pins and connectors against the
possibility of damage to the connections between the hoses and between the hose and tool. Do not exceed the maximum air pressure specifi ed
for the tool.
Never carry the tool, by holding it by the hose.

OPERATING CONDITIONS

You should make sure that that the source of compressed air allows you to create the proper working pressure and that it provides the required
air fl ow. In the case of a too high air pressure, a reducer should be used together with a safety valve. The pneumatic tool must be powered by the
system of a fi lter and lubricator. This will ensure, at the same time, the air, which is pure and moistured by oil. The state of the fi lter and lubricator
should be checked before each use, and possibly clean the fi lter or refi ll shortage of oil in the lubricator. This will ensure proper operation of the
tool and will extend its service life.