The PS-10 230 is a thermostatic valve controller dedicated for underfloor heating system. Is equipped with:
• 9 x voltage outputs (8 outputs dedicated to support thermostatic actuators and 1 output dedicated as pump)
• 1 x voltage-free contact
• 2 x Two-state inputs
The operating conditions of individual devices connected to the controller are programmed in the Sinum Central device. It is designed to be mounted on a DIN rail. It communicates
with the Sinum central device using radio signal.
- Power supply diode
- Manual mode diode
- Current status of the voltage-free output (ON/OFF)
- Communication
1-8 - Current status of the voltage output (ON/OFF)
In order to switch to the manual operation mode, press the manual operation button
in the manual mode. Using the button
signal from the LED labelled 1-8. When the manual mode is on, it is impossible to control the contact via the website or the application. To disable the manual mode, press the
1
button
again and hold it for 1-2 seconds. Once the manual mode has been switched off, all the output status LEDs go off and resume the state set in the Sinum application.
When registering the device, it is recommended to use the heating creator. To run the creator, enter the address of the Sinum Central device in the browser and log in to the
device. In the main panel, click the Settings > System > Heating creator for PS-10/PS-10m and after starting it, add the device by clicking the registration button
the right moment. Then follow the creator to create virtual thermostats, among other things.
The device can be registered also by going to Settings > Devices > Wireless devices >
input and voltage output will be added separately, in addition, virtual thermostats must be created and assigned to the appropriate room.
Technical data
Power supply
Max. power consumption
Operation temperature
Pump max. output load
Potential contacts 1-8 max. output load
Rated load of the voltage-free contact
Acceptable ambient relative humidity
Operation frequency
Max. transmission power
* AC1 load category: single-phase, resistive or slightly inductive AC load
** DC1 load category: direct current, resistive or slightly inductive load.
The full text of the EU declaration of conformity and the user manual are available after scanning the QR code or at
TECH Controllers is not responsible for any damages resulting from improper use of the system. The range
depends on the conditions in which the device is used and the structure and materials used in the object
construction. The manufacturer reserves the right to improve devices, update software and related documentation.
The graphics are provided for illustration purposes only and may differ slightly from the actual look. The diagrams
serve as examples. All changes are updated on an ongoing basis on the manufacturer's website.
Before using the device for the first time, read the following regulations carefully. Not obeying these instructions
may lead to personal injuries or controller damage. The device should be installed by a qualified person. It is not
intended to be operated by children. It is a live electrical device. Make sure the device is disconnected from the
mains before performing any activities involving the power supply (plugging cables, installing the device etc.). The
device is not water resistant.
1
(pressing it once), the user forces a change of the status (ON / OFF) - if the process has been successful, it is confirmed by a light
How to register the device in the sinum system
230V ±10% /50Hz
4W
5 ÷ 50°C
0,5A
0,5A
230V AC / 0,5A (AC1) *
24V DC / 0,5A (DC1) **
<80% REL.H
868 MHz
25 mW
www.tech-controllers.com/manuals
Description
1
- Manual operation button
2
- Registration button
3
- Voltage-free contact output
4
- Voltage outputs
5
- Power supply
Manual mode
1
. The registration button
+
, then briefly press the registration button
To restore factory settings, hold the registration button
After releasing the button, the communication LED will start flashing. Then confirm the
factory settings by pressing the manual operation button
EU Declaration of conformity
Tech Sterowniki II Sp. z o.o., ul. Biała Droga 34, Wieprz (34-122)
Hereby, we declare under our sole responsibility that the thermostatic valve controller
PS-10 230 is compliant with Directive 2014/53/UE.
Wieprz, 01.07.2023
Notes
6
- Two-state inputs
2
is used to switch between the controlled outputs
2
on the device. Each two-state
Factory reset
2
Paweł Jura
Prezesi firmy
The product may not be disposed of to household waste
containers. The user is obliged to transfer their used
equipment to a collection point where all electric and
electronic components will be recycled.
2
at
for at least 3 seconds.
1
.
Janusz Master