CAUTIONS
Do not install the unit in a place where a flammable gas leaks.
• If gas leaks and accumulates in the area surrounding the unit, it could cause an explosion.
Perform the drainage/piping work according to the installation instruction.
• If there is a defect in the drainage/piping work, water could leak from the unit and household
goods could get wet and be damaged.

INSTALLATION OF INDOOR AND OUTDOOR UNITS

Read completely, then follow step by step.
More than 15 cm.
More than 12 cm.
2.3 m or more

Indoor unit

Do not expose the indoor unit to heat or steam.
Select a place where there are no obstacles in front or around the unit.
Make sure that condensation drainage can be conveniently routed away continuously going down-
wards.
Do not install near a doorway.
Ensure that the space on the left and right of the unit is more than 12cm.
Use a stud finder to locate studs to prevent unnecessary damage to the wall.
A minimum pipe run of 3 metres is required to minimise vibration & excessive noise.
The indoor unit should be installed on the wall at a height of 2.3 metres or more from the floor.
The indoor unit should be installed allowing a minimum clearance of 15cm from the ceiling.
Any variations in pipe length will/may require adjustment to refrigerant charge.
LEFT
More than 30 cm.
FRONT
More than 200 cm.

Outdoor unit

If an awning is built over the outdoor unit to prevent direct sunlight or rain exposure, make sure that
heat radiation from the condenser is not restricted.
All manuals and user guides at all-guides.com
More than 12 cm.
BACK
More than 30 cm.
More than 60 cm.
RIGHT
4