Use
2.2
Intended Use
Portable single gas detection instrument for the continuous monitoring
of the concentration of HCl, HF, H
within the working area and in explosion-hazard areas.
2.2.1
Areas subject to explosion hazards, classified by zones
This instrument is intended for use in hazardous areas classified as
Zone 0, Zone 1 or Zone 2, or in mines in which there is a danger of
firedamp, in a temperature range of -20 °C to +50 °C, and in areas
where gases of explosion groups IIA, IIB or IIC and temperature class
T3 or T4 (depending on batteries and rechargeable battery) may be
present.
In mines, the instrument may only be used in areas with a low risk of
mechanical influence.
2.3

Approvals

The approvals are shown on the rating plate, see "Notes on Approval"
on page 294. Do not stick anything on the name plate on the gas
detector.
.
CE marking:
See declaration of conformity on page 295.
18
O
or hydrazine in the ambient air
2
2
3
Use
3.1

Preparations for use

WARNING
!
Use only battery types ABT 01xx, 00xx HBT or HBT 01xx.
See identification on the battery for approved batteries and
the corresponding temperature class.
Replacing components may impair the intrinsic safety.
Before using the instrument for the first time, the enclosed
batteries or a charged T4 NiMH power pack (Order No. 83 18 704)
must be inserted, see "Replacing the Batteries / Rechargeable
Batteries" on page 20.
The X-am-5100 is ready for operation.