3.2. PM VALUE EQUIVALENT TABLE
3.3. REMOTE CONTROL
CR 2032
16
Filter function
This device has a function for regularly replacing the filter units. The exchange time is set to 3000 operating
hours. When this number of operating hours is reached, the indicator light on the control panel will be illumi-
nated continuously, prompting the user to exchange the filter components.
Ensure that you wear safety gloves and an FFP2 facemask whilst cleaning or changing the filters.
Cleaning
Plastic mesh pre-filter
Exchange
Multi-component filter units
(one on each side)
CAUTION:
Press the filter button during normal operation briefly to display the completed operating
hours. First the thousands are displayed, then hundreds, then tens, then the ones. The
example below shows the display for 2802 operating hours:
Child safety feature
When the device is switched on, press the "Child safety" button for 5 seconds and the device will switch to
child safety mode. The buttons on the device and remote control cannot be activated in this mode. Press the
button again for 5 seconds to end child safety mode.
Timer function
When the device is switched on, each time the "TIMER" button is pressed, this will extend the run time of the
air purifier by 1 hour. After this time, the device will switch to Standby mode. The maximum duration is 12
hours. Pressing the button a 13th time shuts o the timer.
PM 1.0 capacity g/m³
5–35
Particle concentration
Low (green)
Speed
Low speed
Speed level
This product is delivered with a remote control that uses button-cell batteries. Please remove the batteries if
the remote control is not in use for a long period of time. The buttons on the remote control match those on
the control panel. The general functions and operating methods are the same.
Note: Remove the battery cover before initial use (for instance with a coin), and remove the protective film
over the batteries. Then replace the cover. Ensure that the "+" symbol is visible on the top of the
batteries.
Normal
Flashes red
--> Clean the pre-filter
No display
--> Then reset by pressing the filter
function button for longer (No reset of
the operating hours)
When 3000 operating hours is reached:
Illuminated red continuously
--> The used filters can be disposed of in
No display
household waste
--> Press the filter function button
for longer to reset the device (Reset of
the operating hours)
36–75
Normal (blue)
High (orange)
Medium speed
High speed
76–150
151–500
Very high (red)
Turbo speed