Download Inhoudsopgave Inhoud Print deze pagina

Important Safety Precautions; Instructions - Pentair FS-15A6-FF12R Installatiehandleiding

Inhoudsopgave

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 8
Customer Support
HERENTALS, BELGIUM (8:30 A.M. to 4:30 P.M.) CET
Website: www.pentairpooleurope.com
Declaration of Conformity
We declare, under our sole responsibility, that the product identified in
this declaration, and to which this declaration relates, are in conformity
with the protection requirements of Council Directive 2006/42/EG
The manufacturer, Pentair, has the right to modify the
products without previous notice for as far as their
characteristics are not really changed by this.
© 2013 Pentair. All rights reserved
This document is subject to change without notice
Trademarks and disclaimers: FreeFlo
trademarks and/or registered trademarks of Pentair and/or its affiliated
companies. Unless noted, names and brands of others that may be used
in this document are not used to indicate an affilitation or endorsement
between the proprietors of these names and brands and Pentair. Those
names and brands may be the trademarks of those parties or others.

IMPORTANT SAFETY PRECAUTIONS

THESE
OPERATING

INSTRUCTIONS

INFORMATION ON THE SAFE, PROPER AND ECONOMICAL OPERATION
OF THE SWIMMING POOL PUMP. STRICT OBSERVATION OF THE
OPERATING INSTRUCTIONS WILL HELP TO AVOID DANGERS,
REDUCE REPAIR COSTS AND SHUTDOWN TIMES AND INCREASE THE
RELIABILITY AND WORKING LIFE OF THE PRODUCT.
ENGLISH
The manufacturer has the right to modify the products
without previous notice for as far as their characteristics
are not really changed by this.
Technical information
Maximum working pressure
Maximum working temperature
Voltage
Rpm at 50 Hz
Protection
Isolation
Sound pressure level of kit
Filter area (m²)
Filter flow rate
Gravel Ø 3-5 mm (kg)
Sand Ø 0.35-0.5mm (kg)
Filter empty weight (kg)
2. GENERAL
Check filtration kit for any evidence of damage due
to rough handling in shipment. If filtration kit is
damaged notify the carrier immediately. The filtration
kit may only be used for the filtering of swimming pool
water, garden pond water or similar applications.
2
, Swimmey
, Azur
and Pentair® are
TM
TM,
TM
CONTAIN
IMPORTANT
INSTRUCTIONS
2 bar
35° C
230 V
2800 min-1
IP 44
F
> 70 dB (A)
Ø 305
Ø 375
Ø 475
Ø 560
0.05
0.11
0.18
0.25
5
6
9
5
12
15
15
30
65
11
15
18
3. INSTALLATION INSTRUCTIONS
Please note: there can be specific needs to use
filtration kits nearby swimming pools, garden ponds
or such places.
The pump should be placed on a flat, solid foundation,
high enough to prevent flooding of the motor.
Install the filter and pump in a sheltered location,
ensuring ventilation and adequate access for
servicing.
Place the filter in its permanent loca-
tion. Make sure you can reach the valve easily. Then
fix the piping. Use only plastic piping. Size all piping
adequately and keep the number of elbows to a
minimum. Use a direct and short suction line with
continuous slope in order to avoid long priming times.
It is essential that the suction line is free of air leaks.
The suction line should always have at least the same
size as the suction inlet of the pump.
4. OPERATION
Look inside and check lower distribution system (6) on
broken or loose laterals (5). Fill tank for 1/3 with water.
Before filling the filter, sand guide (10) should be on
the pipe (4). Fill the filter with the specified quantity of
gravel, afterwards with sand. Remove the sand guide.
Put some vaseline on the O-ring (7) of the valve (8).
Assemble the valve (8) to the filter and tighten with
the clamp ring (9). Connect the piping. Turn the valve
into position "Rinse" and start the pump for at least 1
minute. Before starting the pump, the strainer basket
should be filled with water up to the level of the suc-
tion line. Lubricate the lid O-ring with silicone each
time the lid is removed. Energize the motor, the pump
will prime. The priming time depends on the suction
lift and distance to the pool. Five minutes is a reason-
able time. Pump will not lift more than 2 meter.
If pump does not prime, see troubleshooting guide.
CAUTION: NEVER SHIFT VALVE HANDLE POSITION
WHILE PUMP IS RUNNING. NEVER DISASSEMBLE
VALVE WHILE FILTER IS UNDER PRESSURE.
5. FILTRATION
1. Shift valve handle to position "Filtration"
2. Start the pump
12
3. Note here the pressure of the pressure gauge (11).
20
6. TO CLEAN ( BACKWASH) THE FILTER
120
When the pressure rises approximately 0.5 bar above
24
the recorded pressure it is time to backwash.
1. Shut off the pump
2. Shift the valve handle to "Backwash"
3. Start pump and let it run until water is clean
(about 3 minutes).
4. Shut off the pump
5. Shift valve handle to position "Rinse" and start the
pump
6. Start pump and run for approximately one minute
7. Shut off the pump

Advertenties