Technical Data - Jula Anslut 024207 Bedieningsinstructies

Heteluchtverwarmer
Inhoudsopgave

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 33
EN
Double insulation (safety class II),
does not need to be earthed.
Recycle discarded product
in accordance with local
regulations.

TECHNICAL DATA

Power
Rated voltage
Cord length
Heating capacity
Size
DESCRIPTION
FUNCTIONS
1.
Control panel with display
2.
Air outlet
3.
Air inlet
4.
Power switch/mode selector
FIG. 1
DISPLAY
A.
Temp: Temperature setting
B.
Timer: Setting the timer
C.
Swing: Oscillation
D.
Power switch
Blue light: Low temperature
Red light: High temperature
FIG. 2
INSTALLATION
1.
Fit the two supplied parts of the stand
together and slide the upper part to the
left as shown in the figure.
FIG. 3
2.
Put the back of the unit on a stable table.
The lower part of the housing needs to
18
2000 W
230 V ~ 50 Hz
1.5 m
20 m
H63.5 x W23 x D23 cm
extend slightly beyond the edge of the
table. Put the stand on the bottom of the
housing. The four holes in the bottom of
the housing align precisely with the four
holes in the stand. Screw the stand in
place with the four supplied screws. Do
not overtighten the screws!
FIG. 4
3.
Make sure that the stand is straight and
securely attached to the housing. Put the
unit on the stand.
2
USE
1.
Plug in the plug and put the power switch
on the back of the product in the On
position. An audio prompt is given, and the
display shows the ambient temperature.
The product is in standby mode.
2.
Press the power switch/mode selector
to choose low temperature, high
temperature or off.
Press once for low temperature. The
status light goes blue.
Press again for high temperature.
The status light goes red.
Press a third time to switch off the
product. The status light goes off.
The product switches off, but the fan
continues working for 15 seconds,
which counts down from 15 to 0 on
the display. 00 flashes 3 times, after
which the ambient temperature is
shown. The product returns to
standby mode.
3.
Press the oscillation button to activate/
deactivate oscillation.
4.
Timer: 1 to 24 hours
5.
Temp: The set point temperature
range is between 15 and 40°C. Press
the temperature setting button during
operation to cancel the temperature
setting. The product switches off
automatically if the ambient temperature
exceeds 50°C.