Caution: Some parts of this product can become very hot and cause burns. Particular attention
has to be given where children and vulnerable people are present.
Warning: In order to avoid overheating, do not cover the appliance. Do not place material or
garments on the appliance, or obstruct the air circulation around the appliance, for instance by
curtains or furniture, as this could cause overheating and a fire risk.
The appliance carries a DO NOT COVER warning
Warning: In order to avoid a hazard due to inadvertent resetting of the thermal cut-out, this appliance
must not be supplied through an external switching device, such as a timer, or connected to a
circuit that is regularly switched on and off by the utility.
General Information
Only use filtered water in this appliance.
Always ensure that the appliance is sitting on a level surface.
Although this heater complies with safety standards, we do not recommend its use on deep pile carpets or on long hair
type of rugs.
Please note: Used in an environment where background noise is very low, it may be possible to hear a sound which is
related to the operation of the flame effect. This is normal and should not be a cause for concern.
If this product experiences a power surge for whatever reason the product may cut-out. This is a normal safety feature and
the product will resume operation after 30 seconds.
Once installed, never move this appliance or lay on its back, without draining the water from sump and water tank.
If you intend not using the appliance for longer than a week, drain the water from sump and water tank and dry the sump.
The water tank, sump, sump lid, tank cap and air filters must be cleaned once every week, particularly in hard water areas.
The appliance should never be operated if the lamps are not working.
The lamps should be regularly inspected as described under 'Maintenance' and 'Changing lamps'.
Technical Information
Model No: ENG56-400 E, ENG68-400 E, ENG56-600 E
Heat Output
Nominal Heat Output
Minimum Heat Output
Maximum Continuous Heat Output
Auxiliary Electricity Consumption
In Standby Mode
electronic room temperature control plus week timer
Installation Instructions
This section describes how to set up your fire.
BEFORE YOU START
1. Ensure that all packing items are removed (read any warning labels carefully) and retain all packing for possible future use
e.g. in the event of moving house or returning the appliance to your supplier.
2. Before connecting the appliance, check that the supply voltage is the same as that stated on the heater.
Installation into a Fireplace Mantle
1. When installing this appliance into a fireplace mantle please ensure that you choose a mantle suitable for your appliance
(Fig 18). There is to be an air vent at the front of the fireplace mantle of at least 88cm2. It is essential to ensure that air
can circulate into the appliance – otherwise the Opti-myst flame effect will not operate correctly. This pathway for air must
not be obstructed
2. Remove the 4 spacing brackets on the front of the appliance (Fig 19)
230V
P
1.8
Nom
P
0.9
min
P
1.8
max
P
0.45
Nom
2
240V
2.0
kW
1.0
kW
2.0
kW
0.48
W