Download Print deze pagina

EHEIM 2250 Handleiding pagina 8

Buitenfilter

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 12
English
A
Suction pads with clamping brackets
Outlet elbow
Centrifugal pump
lattice screen (short lugs)
ter canister with fasteners
bow
Intake pipe
Hose clamps.
Filter model 2260 comes complete with a drain tap which should be
screwed into the filter canister and closed. It provides for the interim
drainage of coarse deposits.
B
Elbow connection
k
k
21
Union
22
Base plate.
Slide union nut onto long pipe section of elbow connection and fit
sealing ring. Screw threaded end of elbow connection into pump intake
socket and adjust vertically. Screw union into filter cover, place pump
on base plate so that the elbow connection is inserted into union.
Align pump and secure to base plate with 4 self-tapping screws and
washers supplied. Screw union nut to union, tightening with light pres-
sure. Screw in pressure side union.
C Place lower lattice screen (long lugs facing downwards) in the filter
canister and install filter compound (E). Place top lattice screen (short
lugs facing upwards) in position. Fit sealing ring on filter cover and in-
stall complete filter cover / pump assembly on filter canister. Secure
cover with fastening screws, making sure they are tight.
D Install top cover so that the two fastening clips engage the recesses
in the filter cover handles.
To remove the top cover, press in the two fastening clips below the
handles and push upwards simultaneously.
E Filter compound formation, from base upwards:
Install EHEIM FIX or EHEIM MECH to a depth of approx. 3 – 5 cm as
the lowest filtration layer.
Fill the accompanying net bag with EHEIM SUBSTRAT or EHEIM
SUBSTRATpro or EHEIM LAV, as the main mechanical-biological
filtration compound, and install in the filter canister. The net bag fa-
cilitates subsequent handling for cleaning operations.
Install approx. 3 cm EHEIM FIX as the top layer. Except when carrying
out short-term filtering after adding medication, please do not use
cotton wool, which soon becomes clogged with the high flow rate
through the filter.
Charcoal is only advisable for short-term use if it is necessary to
filter out unwanted substances when the filter is new or after the
addition of medication. It should be replaced by the specified filter
compound formation after a maximum of 3 weeks. Never re-use old
charcoal.
Threaded connector, pressure side
Filter cover
Lower lattice screen (long lugs)
Hose connection, suction side
Strainer
Drain tap (filter model 2260 only)
Union nut
Jet pipe with end-plug
Large sealing ring
Small sealing ring
Cover
Top
Fil-
El-

Advertenties

loading

Deze handleiding is ook geschikt voor:

2260