Step 8
Connect APsystems Microinverters to Grid
a. Please install bi-polar circuit breakers with the appropriate rated current or according to local
regulations. These circuit breakers are mandatory for grid connection.
b. Installation of leakage current breakers or AFCI/GFCI breakers is not recommended.
Step 9
AC Extension Cable
When an AC extension cable is required, users can either connect the AC bus cable and AC extension
cable within a junction box or use a pair of male/female AC connectors provided by APsystems as
optional accessories.
① Bus Cable End Cap
② Male/Female AC Connectors
③ AC Junction Box
④ AC Extension Cable
*Customer using AC junction box, please prepare it by yourself.
Step 10

Complete the APsystems installation map

a. Each APsystems Microinverter comes with 2 removable serial number labels.
b. Complete the installation map by affixing the ID label of each microinverter at the appropriate location.
c. The second serial number label can be adhered to the solar module frame. This label will assist in later confirmation of the microinverter's position without the need to dismantle the PV module.
NOTE:
①. The arrangement of the microinverters' serial numbers in the installation map is designed for standard installations.
②. The Installation Map can be found in the appendix on the last page of User manual.
③. When configuring the ECU, use the ECU_APP (accessible through the EMA Manager) to scan the serial numbers on
the map (refer to the ECU instruction manual for further details).
We, ALTENERGY POWER SYSTEM INC.
Of
Building 2, No. 522, Yatai Road, Nanhu District, Jiaxing City, Zhejiang 314050, China declare under our sole responsibility that the product
Product Description: Grid-tied Microinverter
Model No.: DS3D, DS3D-EU, DS3D-H, DS3D-H-EU, DS3D-L, DS3D-L-EU, DS3D-SH, DS3D-SH-EU
to which this declaration relates, is conformity with the following standards and/or other normative documents.
Safety
Health
EMC
Radio
We hereby declare that all essential radio test suites have been carried out and that the above named product is conformity to all the essential requirements of
directive 2014/53/EU (RED).
Title: Director
Address: Jiaxing, China
Date: 2023/12/18
Zigbee Frequency Range:2405MHz - 2480MHz
Zigbee Maximum Power (EIRP):9.87 dBm

EU DECLARATION OF CONFORMITY

(No. 20240110)
EN 62109-1:2010; EN62109-2:2011
EN IEC 61000-6-1:2019; EN IEC 61000-6-2:2019
EN IEC 61000-6-3:2021; EN IEC 61000-6-4:2019
EN 61000-3-3:2013+A1:2019+A2:2021
EN 301 489-1 V2.2.3(2019-11); EN 301 489-17 V3.2.4(2020-09)
EN 55011:2016+A1:2017+A11:2020+A2:2021
EN 62920:2017+A11:2020+A1:2021
Importer: Altenergy Power System Europe B.V
Address: Karspeldreef 8, 1101 CJ, Amsterdam, The Netherlands
Email: info.emea@apsystems.com
Manufacturer: Altenergy Power System Inc.
Address: Building 2, No.522, Yatai Road, Nanhu District, Jiaxing City, Zhejiang 314050, China
3
EN 62479:2010; EN 50663:2017
EN IEC 61000-3-2:2019+A1:2021
EN 300 328 V2.2.2(2019-07)