TP1 condensate pump installation and operating instructions
GB
1 Notes
The installation and operating instructions in this manual must be followed when installing and operating the TP1
condensate pump. Please read them carefully. We recommend that you keep it close to the pump. Particular
attention must be paid to notes marked as follows:
!
WARNING
Other relevant regulations must also be observed, e.g. accident prevention regulations or internal operating
and safety instructions of the system manufacturer. Failure to follow these instructions can result in the loss
of all entitlement to claim damages.
2 Included items (See Figure  Page )
3 General description
The TP1 condensate pump is an automatic pump for pumping condensation water from condensing boilers, air
conditioning systems, coolers, dehumidifiers or other similar systems. The corresponding regulations on draining
to the sewage system must be observed. If necessary, a neutralising unit must be installed upstream.
Combustible liquids may not be pumped!
!
The condensate pump may not be run dry, as this can destroy the bearings in a very
short period.
WARNING
4 Dimensions (See Figure 4 Page )
5 Specifications
Supply voltage
Frequency
P1 power supply capacity
Current consumption
Degree of protection
Max. delivery head
Max. pump capacity
Noise level (L
)
w
Acid resistance
Max. media temperature
Min. ambient temperature
Floating contact
Tank volume
Packaging dimensions
Packaging weight
Subject to technical changes due to product modifications
6 Curve
7 Installation sequence
8 Installation
The TP1 condensate pump must be installed in dry rooms (frostproof and where the air temperature does
not exceed 60° C) using the installation bracket provided. It is mounted to the wall below the condensate
supply outlet. Ensure that the is mounted horizontally. If floor-mounted, ensure that it is in a stable position
We recommend that you also secure it to the nearest wall.
!
The unit may not be installed in areas where there is a danger of explosion!
www.laing.de
If this instruction is not followed, personal safety risks could ensue.
If this instruction is not followed, the device may not function properly and could be
damaged.
100 - 40 V
50 / 60 Hz
0 Watt
0. – 0.1 A
IP 44 / Class F
45 kPa
450 l/h
46 dB(A)
pH  or higher
+ 60° C (peaks + 90° C)
Not freezing
Break contact, switching capacity 50 VA
0.7 l (usable volume 0.5 l)
15x15x180 mm
1.6 kg
7