FR - CARACTÉRISTIQUES TECHNIQUES
Puissance, kW
2,2 kW
(3 CV)
Tension (±5%), V
230 (50 Hz) 400 (50 Hz) 115 (50 Hz)
Amperage, A
10
Pompe
13 W,
230 V
Vitesse moteur, tr/min
2800
Vitesse de rotation du
2800
disque, tr/min
Protection électrique
IP 54
Profondeur de coupe
Ø 350 = 100
(E) à 90°, mm
Ø 300 = 75
Profondeur de coupe
Ø 350 = 60
(E) à 90°, mm
Ø 300 = 40
Longueur de coupe
E = 15 - 650
(L), mm
E = 50 - 600
Largeur utile (à droite)
Ø 350 = 310
(l), mm
Ø 300 = 300
Dimensions (mm) L
1130 x 630 x 1300 (sur pieds)
x l x h
1130 x 630 x 700 (établi)
Poids (suivant ver-
±92
sion), kg
Refroidissement du
Arrosage dans carter de disque
disque
Capacité minimum du
40
bac, litres
Pompe à eau
13 W - débit : 8 l/mn.
Alimentation
230 V
(H07-RNF 3 x 1,5
400 V
(H07-RNF 4 ou 5 x 1,5
115 V
(H07-RNF 3 x 2,5
Émissions sonores (voir remarque 1)
Niveau de puissance sonore mesuré dB(A)
Niveau de puissance sonore garanti dB(A)
Niveaux sonores (voir remarque 2)
Niveau de pression acoustique au niveau des oreilles
de l'utilisateur, dB(A)
Niveaux de vibrations, a
hv
Poignée, m/s
2
Remarque 1: Émission sonore dans l'environnement mesurée
comme puissance acoustique (L
CE. Le niveau de puissance sonore garanti diffère du niveau me-
suré en cela qu'il prend également en compte la dispersion et les
variations d'une machine à l'autre du même modèle, conformé-
ment à la directive 2000/14/CE.
Remarque 2: Niveau de pression sonore conformément à EN
12418. Les données reportées pour le niveau de pression sonore
montrent une dispersion statistique typique (déviation standard)
de 4,0 dB (A).
Remarque 3: Niveau de vibrations conformément à EN 12418.
Les données reportées pour le niveau de vibrations montrent une
dispersion statistique typique (déviation standard) de 1 m/s
2,9 kW
1,5 kW
(4 CV)
(2CV)
11,5
20
13 W,
30 W,
230 V
115 V
Châssis 56
Tête 36
- Lg 3 m)
2
- Lg 3 m)
2
- Lg 3 m)
2
102
(voir remarque 3)
2,7
) elon la directive UE 2000/14/
WA
GB - TECHNICAL DATA
Power, kW
Voltage (±5%), V
Current, A
Pump
Motor speed, rpm
Disc speed, rpm
Electrical protection
Depth of cut (E) at
90°, mm
Depth of cut (E) at
45°, mm
Length of cut (L), mm
Useable width (to the
right) (l), mm
Dimensions (mm) l x
w x h
Weight (depending
on model), kg
Disc cooling
Minimum tank capa-
city, l
Water pump
Electricity supply
Noise emissions (see note 1)
Sound power level, measured dB(A)
Sound power level, guaranteed dB(A)
96
Sound levels (see note 2)
Sound pressure level at the operators ear, dB(A)
87
Vibration levels, a
Handle, m/s
2
Note 1: Noise emissions in the environment measured as sound
power (L
) in conformity with EC directive 2000/14/EC. The
WA
difference between guaranteed and measured sound power is
that the guaranteed sound power also includes dispersion in the
measurement result and the variations between different machi-
nes of the same model according to Directive 2000/14/EC.
Note 2: Noise pressure level according to EN 12418. Reported
data for noise pressure level has a typical statistical dispersion
(standard deviation) of 4.0 dB(A).
Note 3: Vibration level according to EN 12418. Reported data for
vibration level has a typical statistical dispersion (standard devia-
tion) of 1 m/s
.
2
.
2
2,2 kW (3
2,9 kW (4
CV)
CV)
230 (50 Hz)
400 (50 Hz)
10
11,5
13 W,
13 W,
230 V
230 V
2800
2800
IP 54
Ø 350 = 100
Ø 300 = 75
Ø 350 = 60
Ø 300 = 40
E = 15 - 650
E = 50 - 600
Ø 350 = 310
Ø 300 = 300
1130 x 630 x 1300 (with legs)
1130 x 630 x 700 (bench)
±92
Chassis 56
Head 36
Water spray into the disc casing
40
13 W - débit : 8 l/mn.
230 V
(H07-RNF 3 x 1,5
- Lg 3 m)
2
400 V
(H07-RNF 4 ou 5 x 1,5
2
115 V
(H07-RNF 3 x 2,5
- Lg 3 m)
2
(see note 3)
hv
1,5 kW
(2CV)
115 (50 Hz)
20
30 W,
115 V
- Lg 3 m)
96
102
87
2,7