Using the timer
For the versions fitted with a timer, press the central button (D) to select one of the following
functions:
=
STANDARD HEATING: 15' CYCLE
=
MAXI HEATING: 30' CYCLE
=
STANDARD DRYING: 60' CYCLE
=
MAXI DRYING: 120' CYCLE
Whenever button (D) is pressed, the indicator LED (C) corresponding to the selected function
lights up (the indicator LED is moved clockwise with respect to the reference symbol); after the
various functions are turned on in sequence, all the indicator LEDs turn off and the product
reverts to the thermostat (B) mode.
As soon as the required function is selected, release the button (D); after 3 seconds the product
turns on an operates totally independently of the thermostat (B) setting. Press the central button
(D) again to interrupt the function.
When the appliance starts operating, the indicator LED corresponding to the selected time lights
up. As time goes by, the other indicator LEDs light up to give a rough indication of the time
remaining before the cycle terminates.
When the cycle finishes, the product returns to the thermostat (B) mode and, therefore, only
continues working if the ambient temperature is lower than that set on the thermostat.
Heating/Drying fabrics
Carefully arrange the items without overlapping them in order to optimise heating/drying time and
uniformity.
Do not totally or partially cover the product by hanging towels or clothes directly on the plastic
structure instead of on the rails.
Arrange the items to heat/dry on the rails making sure they do not come into
direct contact with the heating panel.
Never jam towels and/or clothes between the rails and the heating panel.
Using the pilot wire
If the product is fitted with a power cable without plug, it can also be controlled with specific
programmers. The behaviour of the product depends on the voltage applied between the pilot
wire and the neutral wire, as shown in the following table:
ORDER RECEIVED
WAVE SHAPE
NO SIGNAL
COMPLETE
ALTERNATING SIGNAL
NEGATIVE
ALTERNATING SIGNAL
SEMIWAVE
POSITIVE ALTERNATING
SIGNAL SEMIWAVE
CYCLICAL EMISSION OF
A COMPLETE
ALTERNATING SIGNAL
Tc=300S To=3S
To
CYCLICAL EMISSION OF
Tc
A COMPLETE
ALTERNATING SIGNAL
Tc=300S To=7S
Attention: when using the timer function for heating/drying fabrics, pilot wire management is
disable. In this case, the product operates regardless of the signals sent by the programmer and
the thermostat.
6. What to do in case of malfunctions
In the event of overheating, the safety device on the appliance automatically disables the heating
element.
The product will resume automatic operation as soon as the surface temperature returns below
the safety limit.
If you notice irregular operation, damage to the heating panel or to the structure of the appliance,
disconnect the product from the mains power supply and contact your technical assistance centre or
dealer.
7. Maintenance
This product does not require any special maintenance.
Clean the product, especially the heating panel, with a dry cloth once every 6 months.
If the product requires repairing, contact an authorised technical service centre.
When replacing the power cable, use a 2 x 0.75 mm
2
HAR or 3 x 0.75 mm
H05VV-F HAR, depending on the version. This operation, for cables both
with and without plugs, must be performed by qualified personnel and never by the end user in
order to avoid damaging the appliance and jeopardising personal safety.
HEATING
MODE
TEMPERATURE
TEMPERATURE SET
COMFORT
BY THERMOSTAT
3° C LOWER THAN THE
ECO
TEMPERATURE SET
BY THE THERMOSTAT
TEMPERATURE
ANTIFREEZE
MAINTAINED AT
APPROX. 7° C
THE APPLIANCE IS
STOP
SWITCHED OFF
1° C LOWER THAN THE
1° C REDUCTION
TEMPERATURE SET
BY THE THERMOSTAT
2° C LOWER THAN THE
2° C REDUCTION
TEMPERATURE SET
BY THE THERMOSTAT
2
2
H05VV-F HAR, 2 x 1.00 mm