CAUTION: Never use anything to force ice from the evaporator.
Damage may result.
3. Prepare a solution of an appropriate product for the clean-
ing (lime). Do not use hydrochloric acid. We recommend
the use of any NSF approved scale removal product. In
modular appliances the water bucket is filled automat-
ically so we recommend to prepare a previous solution.
4. To start a cleaning cycle, move the switch (4B) to the
"WASH" position (position II). The appliance will drain the
reservoir and refill it. Pour the scale remover solution into
the reservoir.
5. Allow the solution to circulate in the water system for 30-
40 minutes and then set the switch to the OFF position.
6. To purge out the scale remover and residue, set the switch
to the "WASH" position (the appliance will drain the res-
ervoir and refill it) and then set the switch to the OFF po-
sition.
7. Disconnect power and close water supplies.
8. Mix a cleaning solution.
9. Remove the water pump (4C), the curtain (4D) and the
water tray (4E).
10. Clean the metal surfaces, thickness sensor (4F), water
level sensor (4G), adjusting screw (4H), water pump elec-
trode (4I), curtain and water tray with the cleaning solution
using a brush (not a wire brush). ) or cloth.
11. Clean the interior surfaces of the freezing compartment
(including walls, plastic parts of the evaporator, distrib-
utor, etc.) and the front panel with the cleaner solution
using a brush or cloth.
12. Mix a solution of sanitizer using approved (EPA/FDA) sodi-
um hypochlorite food equipment sanitizer to form a solu-
tion with 100 to 200 ppm free chlorine yield.
13. Disinfect all the surfaces of the thickness detector, the
water level detector, the electrode of the water pump, the
curtain and the water tank by applying abundant solution
using a cloth or sponge.
14. Sanitize the interior surfaces of the freezing compartment
(including walls, plastic parts of the evaporator, distribu-
tor etc.) and the front panel applying liberally the sanitizer
solution using a cloth or sponge.
15. Return the water pump, water tank and curtain to their
normal position.
16. Connect power and open water supplies.
17. To start a sanitation cleaning cycle, move the switch (4B)
to the "WASH" position. The appliance will drain the reser-
voir and refill it. Pour the sanitizer into the water reservoir
to get a solution as in the point 12.
18. Allow the solution to circulate in the water system for 20
minutes and then set the switch to the OFF position.
19. To purge out the sanitizer solution and residue move the
switch to the "WASH" position (drain and refill) and allow
the water to circulate for 5 minutes and then move the
switch to the OFF position (drain). Repeat this operation
two more times to rinse thoroughly.
20. Return the panel to their position.
21. Set the switch to the ON position (position I) and discard
the first two ice production.
Maintenance
• Whenever you open up the appliance, check all the water
connections, the condition of the washers and hoses to avoid
leaks and to prevent breakages and flooding.
• Check the operation of the appliance regularly to prevent se-
rious accidents.
• If you see that the appliance is not working properly or that
there is a problem, stop using it, switch it off and contact the
supplier.
• All maintenance, installation and repair work must be car-
ried out by specialised and authorised technicians, or recom-
mended by the manufacturer.
Transportation and Storage
• Before storage, always make sure that the appliance has
been disconnected from the power supply and water connec-
tion or the water tap is closed.
• Store the appliance in a cool, clean and dry place.
• Never place heavy objects on the appliance as this could
damage it.
• Do not move the appliance while it is under operation. Dis-
connect the appliance from power supply when moving and
hold it at the bottom.
Troubleshooting
If the appliance does not function properly, please check the
below table for the solution. If you are still unable to solve the
problem, please contact the supplier/service provider.
Problems
Possible cause
The
Appliance is dis-
appliance
connected from the
does not
mains.
work.
Appliance is switch
OFF (rear).
Front switch in
position "0".
Compressor
Front switch on
doeas not
"WASH" position.
work.
No water in
Lack of water.
tray
Inlet water valve
blocked
Not enough
Water level probe
water to end
too low.
cycle.
Defective drain valve.
Shield splash leaks.
Water tray
Water level probe too
overflows.
high or scaled.
Slab with ice
Thickness probe
is empty or
badly adjusted or
too thick.
scaled.
Difficult
Appliance not leveled
properly - tilted to
releasing
of slab with
back.
ice during
harvest.
Not uniform
Dirty or scaled
flow pattern
distributor.
at evapo-
rator.
GB
Possible solution
Plug in the appliance.
Switch ON appliance.
Set on "ICE" position
(behind front panel).
Check water supply.
Check and clean.
Change probe position.
Disamble and clean.
Check shield position.
Adjust or clean.
Adjust or clean.
Level appliance -
change position.
Perform descaling
procedure.
Remove and clean
distributor
9