Problem
The red LED light
on the boiler
flashes every 0.5
seconds.
The red LED light
on the boiler
flashes every 1.0
seconds.
No water from tap/
steam comes out
of the tap
No boiling water
from tap
No warm water
from tap
Flow rate too low
Cause
The boiler is not filled with
water and is turned on (dry-
on situation).
The sensors are
disconnected and/or the
thermal fuse is broken
because of a faulty
temperature. The heating
element is turned off and
the boiler is in error mode.
• A valve is closed
• A hose is bent
• No water pressure
• The boiler is turned off
• The plug is disconnected
• The earth leakage
protection switch is in
the open position
• The boiler is turned off
• The plug is disconnected
• The earth leakage
protection switch is in
the open position
• The temperature
regulator of the mixing
valve (26) is set to a low
value
• The system contains
scaling or contamination
• A hose is bent
ENGLISH
Solution
This is a locked error
and can only be reset by
unplugging the power
plug.
The appliance needs
to be repaired. Contact
Customer Care and
Service.
• Make sure that all valves
are open
• Make sure that hoses are
not bent
• Make sure that the water
pressure is not less than
0.15 MPa
• Contact your water
supplier if problems are
not solved
• Press the ON/OFF
button (5) for min. 0.5
seconds.
• Connect the plug of the
boiler (3) to the earthed
AC wall socket
• Make sure the earth
leakage protection
switch is in closed
position.
• Press the ON/OFF
button (5) for min. 0.5
seconds
• Connect the plug of the
boiler (3) to the earthed
AC wall socket
• Make sure the earth
leakage protection
switch is in closed
position
• Increase the temperature
with the temperature
regulator (26)
• Make sure that hoses are
not bent
• Contact Customer Care
and Service.
41