Download Inhoudsopgave Inhoud Print deze pagina

Powering Using Poe; Powering Using Optional External Power Supply - Bose Professional ControlSpace EX-UH USB/Headset Dante Endpoint Installatie- En Bedieningshandleiding

Inhoudsopgave

Advertenties

Installation and Operation
Connecting and Powering
The endpoints can be powered using Power-over-Ethernet (PoE+) or the optional external 12 V DC
power supply.
Note: Make all network and audio connections to the endpoint before the power is applied.

Powering Using PoE+

Use PoE+ to connect a single endpoint, or to daisy-chain a maximum of three (3) endpoints:
Connect a PoE+ enabled port on the Dante network switch to the Dante/PoE+ network port on the
1.
first endpoint in the chain, using a Cat 5 cable.
2. To connect additional endpoints, follow the instructions below for Connecting Multiple Endpoints.
To daisy-chain more than three endpoints, use an external power supply instead of PoE+.
Note: When determining the number of ControlSpace EX endpoints that can be daisy-chained for
power, you must consider total power consumption. Add the power of each endpoint (6 watts each) and
all connected microphones. Microphones typically consume phantom power as well as LED power (if
applicable). The total value must not exceed (with some margin) the power source capacity. When using
PoE as a source, do not exceed 12 watts in the chain. With PoE+, the total power must not exceed 24
watts. If you exceed the total power available on one PoE/PoE+ cable, consider running a second Cat 5
cable, or use a Bose Professional accessory power supply.

Powering Using Optional External Power Supply

Use the optional EX Endpoint Power Supply or a 12 V DC Limited Power Source (LPS) or Class 2 Power
Supply (as defined in the IEC60065/UL60950 safety standard) to daisy-chain a maximum of six (6)
endpoints:
1.
Connect a port on the Dante network switch to the Dante/PoE+ network port on the endpoint, using
a Cat 5 cable.
2. Connect the power supply to +12 V DC IN on the first endpoint in the chain.
Note: For instructions on connecting additional endpoints, see Connecting Multiple Endpoints on page 13.