All manuals and user guides at all-guides.com
"address +1" will be transmitted (e.g. when A3 is programmed as the
base address then the Marmitek X10 address A4 will be sent by using
input 2). If the status in the MicroModule was ON, an OFF command
will be transmitted. If the status in the MicroModule was OFF, an ON
command will be transmitted. Through this transmission, other
Marmitek X10 modules can be switched remotely over the power line
or Macro's setup in the computer interface can be activated.
Mounting Instructions
WARNING! ALWAYS SWITCH OFF THE MAIN MASTER SWITCH BEFORE
INSTALLING THE MICROMODULE.
To install the MicroModule AWM2 the following wiring is required at
the module installation point.
1. Neutral
2. Phase 230V
3. Load. This wire runs
directly to the load.
• Take the wall switch out of the wall outlet.
• Disconnect all wires from the switch.
• Pull an additional Neutral-wire in case this one is missing.
MICROMODULE AWM2
5