5.4 Programming
5.4.1
S3: Adjusting the flush duration
Refer to page 2 for a graphic illustration of program selection.
> Hold the magnetic key in front of the right signal eye until 6 signal tones sound,
with a longer interval between the 5th and 6th signal tones (approx. 6 sec.).
> Remove the magnetic key.
The control confirms the program selection by 2 short signal tones.
> Hold the magnetic key in front of the right sensor eye again within 4 sec.
Flushing starts. A signal tone sounds at a 1 second interval at the same time.
> Leave the magnetic key in front of the right signal eye (min. 1 sec., max. 4 sec.) until
the desired flush duration has been set.
> Remove the magnetic key
The control confirms the setting for the new flush duration by 2 short signal tones.
The flush duration has been changed.
Finally, the control reactivates the preset flushing program.
5.4.2
S4: Setting the hybrid interval
Refer to page 2 for a graphic illustration of program selection.
> Hold the magnetic key in front of the right signal eye until 7 signal tones sound, with
a longer interval between the 5th and 6th and the 6th and 7th signal tones (approx.
6 sec.).
> Remove the magnetic key
The control confirms the program selection by 2 short signal tones.
> Hold the magnetic key in front of the right sensor eye again within 4 sec.
An audible signal sounds every second.
> Hold the magnetic key in front of the right sensor eye (min. 1 sec.=10 users, max.
5 sec. = 50 users) until the desired interval is reached.
> Remove the magnetic key
The controller confirms the setting of the new hybrid interval by making 2 short au-
dible signals.
The hybrid interval is now changed.
Finally, the control reactivates the preset flushing program.