The hot air exhaust hose is not connected
or blocked.
Temperature setting is too high.
Air inlet or outlet is blocked.
The ground is not level or not flat enough.
Noisy
The sound comes from the flowing of the
refrigerant inside the appliance.
Code "E2" on the
Room temperature sensor failed.
digital display
Code "E3" on the
Evaporator temperature sensor failed.
digital display
Code "E4" on the
Water-full warning
digital display
TECHNICAL DATA
Below data for your operating reference
Model
Rated voltage
Rated frequency
Rated input
Rated current
Cooling capacity
Moisture removal (L/H)
Air flow
Max. transmitting power
Frequency range
We, Emerio, declare under our sole responsibility that the product: PAC-125153.1 is in conformity with the
essential requirements and other relevant requirements of the RED Directive (2014/53/EU)
The complete CE declaration is available at the following address: www.emerio.eu
ERP INFORMATION
Trademark
Model identification
Sound power (cooling)
Name of refrigerant
Rated power input for cooling (kW)
Rated energy efficiency ratio
GWP (kgCO
eq)
2
Energy efficiency class
Energy consumption for double ducts appliances
(kWh/h)
Energy consumption for single duct appliances
(kWh/h)
Connect or clean the hot air exhaust
hose.
Reset the temperature.
Clean the air inlet or outlet.
Place the appliance on a flat, level
surface if possible.
It is normal.
Replace the room temperature sensor.
Contact authorized service technician
for repair.
Replace evaporator temperature sensor.
Contact authorized service technician
for repair.
Drain out the water.
PAC-125153.1
220-240V
50Hz
950W
4.2A
9000BTU
1.0
300m³ /h
20dBm
2412 - 2472MHz
Value
Emerio
PAC-125153.1
64.3dB(A)
R290
0.95
2.6
3
A
N.A
0.96
- 13 -