6. GENERAL SPECIFICATIONS
Mechanical features
Dimensions
170 x 80 x 50 mm
Weight
320 g (with batteries)
Packing blister
266 x 132 x 70 mm
Power supply
Batteries
2 x 1.5V AA
Battery life
approx. 500 hours in VLowZ/VAC without backlight
Climatic conditions
Reference temp.
23°C ± 3°C
Use temperature
–20°C to 55°C
Storage temp.
–40°C to 60°C
Relative humidity
< 90% RH (up to 45°C) without condensation
Protection rating
IP 54
Safety
IEC 61010-1/EN 61010-02-030/EN 61010-2-033
Insulation
class 2 double isolation
Pollution degree
2
Use
indoor
Altitude
< 2000 m
Category
CAT III, 600 V max. to earth
EMC
complies EN 61326-1
34
BDA_Digital-Multimeter-Professional_B205xH115.indd 34
7. TECHNICAL SPECIFICATIONS
(See Appendix, p. 100)
Referal conditions
Temperature
+23°C ± 3°C.
Humidity
45% to 75% RH
Supply
Full battery (no low bat signal display) or
accu. 1.5 VAA Ni-MH
Freq. for AC signal
45–65 Hz
Pure AC signal
No other rotating magnetic field
No other electrical field
General measure characteristics
• in DC AC ≤0,1% of the DC signal
• in AC DC < 0,1% of the AC signal
13.01.17 13:02