6. Troubleshooting
a.) If the pump doesn't reach the final operating pressure air may have penetrated the
system.
=> Hold the crimping head lower than the electric pump and actuate the foot switch
(Pos.-No. 7) until the dies have contacted each other. Repeat this procedure 2 or 3
times.
If the pump is still not reaching the full pressure repeat this process again until the
pump works properly.
Should the malfunction not be corrected by this operation the pump must be returned to
the manufacturer.
b.) The pump loses oil.
=> Return the tool to the manufacturer. Do not open or destroy the seals of the tool.
7. Putting out of service/waste disposal
This unit is subjected to the scope of the European WEEE (2002/96/EG) and RoHS
(2002/95/EEC) directives.
The WEEE directive regulates the collection and the environmental friendly recycling of
electro and electronic units. Information about this can be found in our home page
www.Klauke.com
The RoHS directive bans new electrical and electronic equipment put on the market which
contains more than 0,1 weight percentage lead, mercury, hexavalent chromium,
polybrominated biphenyls (PBB) or polybrominated diphenyl ethers (PBDE) and 0,01
weight percentage cadmium per homogeneous material.
Battery cartridges (Pos.-No. 7) must be specially disposed of according to the EEC Battery
Guideline.
Attention
Do not dispose of the unit in your residential waste. Klauke has no legal
obligation to take care of their WEEE outside Germany unless the product has
been shipped and invoiced from inside your country by Klauke. Please contact
your distributer to find out more how to get your tool recycled environmental
friendly.
All manuals and user guides at all-guides.com
under 'WEEE & RoHS'.
page 21